Chapter 3
3–16
BlastMate III Operator Manual
without the microphone turned on. To choose a setting, display it on the BlastMate III display
then press the
Enter
key.
f. Microphone Type
(Compliance Module Only)
Two types of microphones may be connected to the BlastMate III: Linear “L” and “A” Weight.
The BlastMate III must be configured to the microphone type being used to ensure the proper
measurement units and data analysis techniques are used during recording. This setting tells the
BlastMate III which microphone you are using. To check the type of your microphone, read the
label on the side of the microphone. All Instantel microphones have a model number.
Lin Mic
identifies a linear microphone.
A Mic
identifies an “A” Weight microphone.
To select a microphone type, press the Setups
Special
key when the Main Window is displayed.
Press the
Enter
key repeatedly to scroll through the windows until the Microphone Type Window
appears. Press the
Up
or
Down
key to display the two microphone types, Linear or “A” Weight.
To choose a setting, display it on the BlastMate III display and press the
Enter
key. On eight
channel monitors, set the microphone type for the second microphone, Mic2.
g. Microphone Units
(Compliance Module Only)
The measurement units used on the microphone channel depend on the microphone type and
measurement system being used. For Linear “L” microphones, you have the choice between psi
(L), dB (L), or pa. (L). For “A” weight microphones, units are dB (A) only. For this reason, when
you chose the “A” Weight microphone type, this window does not appear on the BlastMate III
display.
To choose a microphone measurement unit, press the Setups
Special
key when the Main Window
is displayed. Press the
Enter
key repeatedly to scroll through the windows until the Microphone
Units: Window appears. Press the
Up
or
Down Arrow
key to display the three microphone unit
choices. Press the
Enter
key to select a measurement unit when it appears on the display.
h. Geophone Type
(Compliance Module Only)
Two types of geophone may be connected to the BlastMate: a Standard Geophone or a 4.5 Hz
Geophone.
To select a geophone type, press the
Right Arrow
key and the
Setups
key together. Press the
Enter
key to scroll the windows until the Geophone Type Window appears. Press the
Right
Arrow
key to display the two microphone types, Standard or 4.5 Hz. To choose a setting, display
it on the BlastMate III display and press the
Enter
key.
Note that for the 4.5 Hz Geophone, the unit will perform a continuity test when Sensorcheck is
run instead of the standard Sensorcheck test.
i. Geo Alarm Level
(Compliance Module Only)
The Geo Alarm Level controls the triggering of an optional remote alarm (711A1401). On eight
channel monitors, the geo alarm level operates on channels one to four only.
The remote alarm sounds two alarms: warning and alarm. The warning alarm sounds when event
activity exceeds the geophone trigger level. The geophone alarm level can be set to a higher level
than the geophone trigger level. This allows for the triggering of a second alarm at the higher
level.
For example, in pile driving operations the remote alarm triggers a warning when activity exceeds
the trigger level for the geophone, notifying the operator that the pile driving activity has
exceeded that set level. The second alarm triggers when activity exceeds the geophone alarm
level, set to a higher level, notifying the operator that operations should cease immediately.
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...