Compliance Module
BlastMate III Operator Manual
3–17
To set the geophone alarm level, press the Setups
Special
key when the Main Window is
displayed. Press the
Enter
key repeatedly to scroll through the windows until the Geo Alarm
Level Window appears. Use the
Up
or
Down
and
Left
or
Right Arrow
keys to set the alarm
level. Press the
Enter
key to save your setting.
j. Mic Alarm Level
(Compliance Module Only)
The Mic Alarm Level controls the triggering of an optional remote alarm (711A1401). On eight
channel monitors, the Mic Alarm Level operates on channels one to four only.
The remote alarm sounds two alarms: warning and alarm. The warning alarm sounds when event
activity exceeds the microphone trigger level. The Mic Alarm Level can be set to a higher level
than the microphone trigger level. This allows for the triggering of a second alarm at a higher
level. See the Geo Alarm Level section, above, for an example.
To set the Mic Alarm Level, press the Setups
Special
key when the Main Window is displayed.
Press the
Enter
key repeatedly to scroll through the windows until the Mic Alarm Level Window
appears. Use the
Up
or
Down
and
Left
or
Right Arrow
keys to set the alarm level. Press the
Enter
key to save your setting.
k. Serial Connection
This sets the BlastMate III to communicate with a computer using the BlastMate III PC
Connecting Cable (712A2301) or via a modem over telephone lines or radio frequencies. You
must set the BlastMate III to the proper serial connection before starting communications. To
communicate with a computer using the connecting cable, choose the Direct setting. To
communicate using modems, choose the Via Modem setting. Set the baud rate on the monitor to
match the baud rate of your computer or modem.
To choose the serial connection, press the Setups
Special
key when the Main Window is
displayed. Press the
Enter
key repeatedly to scroll through the windows until the Serial
Connection: Window appears. Press the
Up
or
Down Arrow
key to display the two choices.
Select Direct if you are connecting to a computer with the BlastMate cable or Via Modem if you
are using modems. Press the
Enter
key to select a choice when it appears on the display.
l. Direct Baudrate or Modem Baudrate
This sets the baudrate for the serial connection method chosen in the previous step, either direct or
via modem. For direct, choose a baudrate of 38400. For modem communications, choose a
baudrate supported by the modems you are using.
m. Call Home
This setting is used to setup the monitor for use with the Auto Call Home feature of the BlastWare
III software. With Auto Call Home, your monitor can be setup to automatically download results
either after an event, or at specified times. You must have a modem and phone line connected to
the unit in order to use this feature. In addition, you must setup Auto Call Home within BlastWare
III on your PC. Please refer to the BlastWare III Operator Manual (p/n 714U0301) for information
on how to configure Auto Call Home and setup modems for use with a monitor.
To turn Call Home on, select Enabled. If you do not wish to use this feature, select Disabled.
To set Call Home, press the Setups
Special
key when the Main Window is displayed. Press the
Enter
key to scroll through the windows until the Call Home: Window appears. Press the
Up
or
Down Arrow
key to display either Enabled or Disabled. Press the
Enter
key to save your setting.
Note
: Auto Call Home is supported by BlastMate III units with a serial number of 6000 or higher.
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...