Chapter 5
5–2
BlastMate III Operator Manual
Figure 5.1 For Wall Installations of the Standard Transducer,
Switch the Positions of the Transverse and Vertical Geophones.
Place the standard transducer on the wall with the arrow pointing in the direction of the event.
Mark the position of the bolt. Install the bolt into the wall according to the manufacturer’s
instructions. If using the leveling plate, secure the leveling plate to the standard transducer with
the three screws provided. Slide the standard transducer over the bolt with the arrow pointed in
the direction of the event. Slide a 3/8 inch (9.5 mm) washer and a 3/8 inch (9.5 mm) lock washer
over the bolt. Screw on the retaining nut to hold the unit in position. Level the assembly by
placing a level across the standard transducer’s top cover and adjusting the leveling feet. The
integrated bubble level does not work when installing the leveling plate on a wall. Tighten the
retaining nut on the bolt to secure the installation. Press the
Test
key to check your sensors using
Sensorcheck.