background image

Registered Office: Unit 17/18 Gunnels Wood Park, Gunnels Wood Road, Stevenage, Herts SG1 2BH, UK • Registered No. 4388957 • VAT No. 795788835

 

Credit card reader

 

None (optional IC card reader, ID card, ID card)

 

Face Detection

 

Supports detection and tracking of multiple people at the same 

time

 

Face library

 

Up to 30,000

 

1:N face recognition

 

Support

 

1:1 face comparison

 

Support

 

Function

 

Stranger detection

 

Support

 

Identify distance 

configuration

 

Support

 

UI interface 

configuration

 

Support

 

Upgrade remotely

 

Support

 

Interface

 

Interfaces include device management, personnel

/ photo management, record query, etc.

 

Deployment method

 

Support public cloud deployment, privatized deployment, 

LAN use, stand-alone use

 

Temperature detection

 

Support

 

Temperature detection 

distance

 

1 meter (optimal distance 0.5 meter)

 

Infrared 
thermal 
imaging 
module

 

Temperature 

measurement 

accuracy

 

≤ ±0.5℃

 

Temperature measurement 

range

 

10℃~42℃

 

Pixels

 

32 X 32 dots (total 1024 pixels)

 

Abnormal temperature 

alarm

 

Support (temperature alarm value can be set)

 

Power

 

DC12V(±10%)

 

Operating temperature

 

0℃~40℃

 

General 

parameters

 

Storage temperature

 

-20℃~60℃

Power consumption

 

13.5W(Max)

 

Size

 

Standard:274.24*128*21.48(mm)

 

IC card / ID card:296.18*132.88*25(mm)

 

Packing list

 

Machine * 1, power adapter * 1

 

Summary of Contents for FaceScan1000

Page 1: ...Registered Office Unit 17 18 Gunnels Wood Park Gunnels Wood Road Stevenage Herts SG1 2BH UK Registered No 4388957 VAT No 795788835 Product Manual June 2020 ...

Page 2: ...Scan app As soon as you place your face in the field of view on the screen indicated by a cut out of a human the device springs to life and instantly takes your temperature It is a good idea to setup the WiFi connection and change the time date prior to starting In order to get into the setup menu of the device you must connect a USB mouse with a scroll wheel Right Click the mouse and then on the ...

Page 3: ...App menu system using the mouse click on the center scroll wheel This will bring up the password screen Enter the password 123456 and this time you will see the menu setup screen As a stand alone version click on Application settings and make the changes you require If you are connecting to our SAAS model you will need to click on Login Management and follow the instructions that came with your SA...

Page 4: ...ation is stored in a file on the unit that can be loaded onto an external USB stick if required Simply plug in a USB stick into the yellow USB port enter the setup menu enter the Pass Record section and click export If you want to use the Face Recognition section you need to first add faces This can be from the Face Data Entry menu on the main menu page Simply put the desired face between the cros...

Page 5: ...d IR dual photo flood light Size 8 0 inch IPS LCD screen Screen Resolution 800 1280 Touch Not supported optional support CPU RK3288 quad core Processor Storage EMMC 8G Network module Ethernet and wireless WIFI Audio 2 5W 4R speakers USB 1 USB OTG 1 USB HOST standard A port Serial communication 1 RS232 serial port Interface Relay output 1 door open signal output Wiegand One Wiegand 26 34 output one...

Page 6: ...Interfaces include device management personnel photo management record query etc Deployment method Support public cloud deployment privatized deployment LAN use stand alone use Temperature detection Support Temperature detection distance 1 meter optimal distance 0 5 meter Infrared thermal imaging module Temperature measurement accuracy 0 5 Temperature measurement range 10 42 Pixels 32 X 32 dots to...

Page 7: ...ark Gunnels Wood Road Stevenage Herts SG1 2BH UK Registered No 4388957 VAT No Installation Notes Sizes Port description Registered Office Unit 17 18 Gunnels Wood P 795788835 ...

Page 8: ...lation like the one below this is normally at the middle or front side of the gate Singlechannelgate Dual channel gate 1 Unscrew the nut on the bottom of the gate head post thread the cables out of the nut and remove the nut fully 2 Next thread the cables through your 35mm hole you cut previously thread the cables through the hole and then after fitting the cables through the nut use the nut to fi...

Page 9: ...o unit is secured in place Make sure the face of the Instascan unit is facing the side of the plate with no screw holes 6 Now the Instascan unit is secured to the mounting plate you need to hold the unit in place near the top of the mounting pole and connect the power connector from the mounting pole to the corresponding connection coming from the unit 7 Once connected carefully feed excess cable ...

Page 10: ...stered Office Unit 17 18 Gunnels Wood Park Gunnels Wood Road Stevenage Herts SG1 2BH UK Registered No 4388957 VAT No 795788835 9 Plug in to power outlet Unit should now be installed powered and ready to use ...

Page 11: ...the gate please make sure that the product is installed firmly If the product does not work properly please contact the after sales service personnel Do not disassemble or modify the product in any way The company does not assume any responsibility for problems caused by unauthorized modification or repair Do not immerse the product in water When the product is installed outdoors try to use it wit...

Page 12: ...VAT No 795788835 Wire interface definition The interface of each terminal is defined as follows n Relay Terminal electrical definition Pin1 COM Pin2 NO n Wigan input Terminal electrical definition Pin1 D0_IN Pin2 D1_IN Pin3 12V Pin4 GND n Wigan output Terminal electrical definition Pin1 D0_OUT Pin2 D1_OUT Pin3 GND ...

Page 13: ...evenage Herts SG1 2BH UK Registered No 4388957 VAT No 795788835 n 232 serial port Terminal electrical definition Pin1 232_RX1 Pin2 232_TX1 Pin3 GND Esprit Digital Ltd Unit 17 18 Gunnels Wood Park Gunnels Wood Road Stevenage SG1 2BH 44 208 731 3121 www espritdigital com ...

Reviews: