WHAT IS INSTEON?  

Since its inception in 2005, INSTEON has become a best-selling home-control networking technology, 
offering more reliability and flexibility than any other home management system on the market.  INSTEON 
systems are simple, reliable, and affordable. Simple, because each device takes mere minutes to install. 
Reliable, because every INSTEON device works as a network repeater, ensuring your commands will not 
be lost. Affordable, because INSTEON can be integrated into any number of devices easily and at a very 
low cost. An INSTEON home grows in value with each added INSTEON device, making life more 
convenient, safe, and fun. 

How Does INSTEON Work? 

What makes INSTEON the most reliable home automation network is its dual-mesh network. INSTEON 
devices use both radio frequency (RF) signals and the home’s existing wiring to talk to each other. In an 
INSTEON network, every INSTEON device also acts as a repeater, receiving and sending every 
message to all other devices in the network. So by integrating more INSTEON devices you will strengthen 
the network and ensure no commands will be lost.  

No central controller or networking setup is required with an INSTEON network. Simply install your 
devices and then use a series of button presses or taps to Link your devices together. Throughout this 
Owner’s Manual, you may see the terms “Controller” or “Responder”. These generic INSTEON terms 
refer to the components of an INSTEON scene, and are used on a scene-by-scene basis.  

 

Controller 

– sends INSTEON commands to other devices 

 

Responder 

– reacts to commands sent out by another INSTEON device 

An INSTEON device may act as a Controller, Responder, or sometimes both.  

INSTEON networks are also extremely secure. Each INSTEON device is assigned a unique INSTEON 
ID, so unless neighbors or would-be hackers have access to your particular device’s INSTEON ID, they 
won’t be able to control your home, even if they are using similar products.  

INSTALLATION 

Preparing to Install LampLinc 

CAUTION

 

Read and understand these instructions before installing and retain them for future reference. 

LampLinc is intended for installation in accordance with the National Electric Code and local regulations 
in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. 
LampLinc is not designed nor approved for use on power lines other than 120V 60Hz, single phase. 
Attempting to use LampLinc on non-approved power lines may have hazardous consequences. 

 
Prior to installing LampLinc, please review the entire installation procedure and take the following 
precautions:  

  Use indoors or in a properly insulated and weatherproof electrical box only  

  Don’t plug LampLinc into an outlet controlled by a switch because if the switch is inadvertently 

turned off, LampLinc won’t have power 

  Don’t plug LampLinc into a filtered power strip or AC line filter 

  Be sure the device you want to control is working and that the device’s built-in switch is in the on 

position 

Page 4 of 14 

 

Summary of Contents for LampLinc 2456D3

Page 1: ...LampLinc INSTEON Plug In Lamp Dimmer Module 3 Pin Model 2456D3...

Page 2: ...emoving the X10 Primary Address 9 Setting the X10 On Level and X10 Ramp Rate for the X10 Primary Address 9 Enabling Disabling X10 Resume Dim 9 ADVANCED X10 PROGRAMMING OPTIONS 10 Remotely Setting the...

Page 3: ...to other INSTEON devices in minutes Controls standard incandescent lighting devices up to 300 Watts Indicates INSTEON setup mode activity with a Status LED Dims the load up to 32 brightness levels Ch...

Page 4: ...ON terms refer to the components of an INSTEON scene and are used on a scene by scene basis Controller sends INSTEON commands to other devices Responder reacts to commands sent out by another INSTEON...

Page 5: ...ou have any questions please call INSTEON Gold Support Line 800 762 7845 Installing LampLinc 1 Plug the lamp device also called the load you want to control into the outlet on the bottom of LampLinc 2...

Page 6: ...vices 1 Set the Controller to Unlinking Mode For most Controllers press hold an On or Scene button for 10 seconds twice or the Set button for 3 seconds twice You will have 4 minutes to complete the ne...

Page 7: ...5 74 0 3 52 61 0 5 39 48 2 0 26 35 4 5 13 23 6 5 1 10 8 5 Less than 1 9 0 NOTE If the load is ramping to less than full brightness then the time it will take will be proportionately less For instance...

Page 8: ...Triple tap the Set button on LampLinc The LampLinc Status LED should stop blinking and turn on solid 3 Test that Load Sensing has been enabled by turning the load on and off from its built in switch T...

Page 9: ...uld continue blinking The load should flash once You will have 4 minutes to complete the next step before Unlinking Mode automatically times out 3 Using an X10 controller send the X10 address you wish...

Page 10: ...e brighter is faster dimmer is slower The following table gives the approximate relationship between the brightness you set in this step and the Ramp Rate you get Approximate Brightness Level Ramp Rat...

Page 11: ...nit code 3 Use the buttons on a Linked Controller to adjust the load to the desired Ramp Rate brighter is faster dimmer is slower The following table gives the approximate relationship between the bri...

Page 12: ...command up to five times While using at least one dual band device is required when using an RF only device at least two dual band devices are recommended in any INSTEON network to ensure reliable co...

Page 13: ...ampLinc See Resetting LampLinc to its Factory Default Settings The bulb filaments are vibrating Use rough service 130 Volt or appliance grade bulbs to reduce the noise The load is buzzing when on or d...

Page 14: ...e at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to Smarthome Inc ATTN Receiving Dept 16542 Millikan Ave Irvin...

Reviews: