12
FM
Control Voltage
Signal Router Toggle:
Routes the signal present at the
FM Input
to
different parts of the circuit. Incoming signals will always modulate the
frequency of
neóni
(when unattenuated), regardless of the
toggle position.
•
If the toggle is in the left position, the positive portion of the incoming
signal is clipped and then routed to the
Hard Sync Input
. This can
help stabilize the organic nature of through-zero FM.
•
If the toggle is in the centre position, additional routing is disabled.
•
If the toggle is in the right position, the incoming signal will be routed
to the
CV Input
before the signal reaches the
FM Attenuator
. This
allows the incoming signal to be connected to the
FM Input
to be
scaled by the
FM Attenuator
(for frequency modulation) and the
CV Attenuator
(for general-purpose modulation). The additional
parameter controlled is selected by the
CV Destination Switch
Connecting a signal to the
CV Input
will break the normalled routing
from the
FM Input
.
0
2.5
-2.5
0
2.5
-2.5
SYNC
0
2.5
-2.5
To CV Input
DC
FM
0
5
- 5