Log files
The device can record events and write them to log files. These contain system sta-
tus, messages as well as events caused by the user.
The following log file settings can be made in the web interface under
Configura-
tion > System
in the
General Settings
section.
•
enable / disable, default: enable
The log entries are displayed in the web interface under
Monitoring > Logging
. The
following table is an example of the log entries.
Time
Type
Description
0 day(s) 00:00:00
device
power on
0 day(s) 00:00:00
fault contact
inactive
0 day(s) 00:00:00
device
booted
0 day(s) 00:00:01
interface
interface 6 link up
0 day(s) 00:00:10
user
web interface login
0 day(s) 00:00:30
user
configuration file loaded
0 day(s) 00:00:30
fault contact
inactive
Table 1 2: ETSM
–
log entries
The log file can also be downloaded from the device. To download the current log,
the
Download Current Log
button is available in the web interface under
Monitor-
ing > Logging
.
If a log file reaches a size of 1 MB, logging will continue in a new log
file with incremented number. The file with the highest number in its
name has the newest log entries therefore.
The internal memory has capacity for two such files. If they are full,
the first will be deleted and number of the other will be decremented
and a a new file will be written.
All log files can be copied to an USB flash drive under
Maintaining > Settings
using
"Copy to USB", "Logging Files".