INSYS ISDN TA 4.0
Functions
9.5.2
Configuring the Remote Configuration Number
You can assign an own, dedicated phone number for the INSYS ISDN TA 4.0 for
remote configuration access.
The phone number of the caller is not requested in default setting .
Configuration with HSComm
A remote configuration with HSComm is not possible.
Configuration with AT commands
In order to determine a separate remote
configuration number, use the command
AT**rmsn=<phonenumber>
9.5.3
Configuring the Remote Configuration Password
You can enter a password at the INSYS ISDN TA 4.0 to increase the safety of the
remote configuration.
No password is entered in default setting.
Configuration with HSComm
A remote configuration with HSComm is not possible.
Configuration with AT commands
In order to define a password, use the
command
AT**rpwd=<password>
9.5.4
Configuring the Permitted Callers for Remote Configuration
You can create a list with up to 10 (3 for FW < 1.027) phone numbers, which are
permitted as caller numbers for remote configuration of the INSYS ISDN TA 4.0.
The INSYS ISDN TA 4.0 ignores each incoming call with a phone number, which
does not match with one of the entries of the list. The INSYS ISDN TA 4.0
compares the number of the caller with each entry of the list for this. The
comparison starts with the last digit of the phone number. It will be compared until
an entry matches a caller number. If a table entry contains only an asterisk "*",
each incoming call is accepted. If the table is empty, the INSYS ISDN TA 4.0
accepts each caller for remote configuration.
49