10
Technical Data
The maximum current load is 1 A DC or 0.5 A AC.
Terminal Labeling
Description
11
OUT 1-NC
Output 1 – normally closed
contact
12
OUT 1
Output 1, COM
13
OUT 1-NO
Output 1 – normally open
contact
14
OUT 2-NC
Output 2 – normally closed
contact
15
OUT 2
Output 2, COM
16
OUT 2_NO
Output 2 – normally open
contact
3.6 Transmission Standards / Protocols
•
IEEE 802.11b
•
ARP, ICMP, TCP/IP, UDP/IP (INSYS WLAN serial)
•
ARP, IP, ICMP, TCP/IP, UDP/IP, http, DHCP (INSYS WLAN bridge)
3.7 Approvals
The INSYS WLAN serial and INSYS WLAN bridge both bear the CE symbol of conformity.
This symbol is a declaration that on account of its design and implementation, this
modem is in compliance with the currently valid versions of the following EC directives:
•
89/336/EEC (EMC
directive)
•
73/23/EEC
(Low voltage directive)
Approvals:
•
CE
3.8 Firmware
INSYS WLAN serial:
Date:
June 2004
Version: 1.10
INSYS WLAN bridge:
Date:
March 2004
Version: 1.00
version 1.01 / 10.04