12
Installation
4.3 Installation
Steps
1.
Mounting on DIN rail:
Simple snap-on
2.
Attaching the antenna(s)
Simple screw-on; please do not bend the antenna.
3.
Connecting the RS232 or the Ethernet connection
Plug the enclosed RS232 interface cable (INSYS WLAN serial) or the network cable
(INSYS WLAN bridge) into the cover front and connect it with the PC.
4.
Connecting the Power Supply:
a) Connecting the ground wire GND (terminal 1)
b) Connecting the power supply 10..60 V DC (terminal 3)
Attention!
For mass production devices, the supply voltage input 50…80 V DC at
terminal 2 is optional and not equipped.
c) Switching on the power supply
After successful installation, the power LED will be green.
Attention!
When the device acts faulty or abnormal, please disconnect the power
supply immediately. For those cases, please refer to your supplier. To
protect your guarantee claims, please
do not intervene
with the device.
The further implementation or configuration of the INSYS WLAN bridge is described in
Chap. 5; INSYS WLAN serial is described in Chap. 6.
version 1.01 / 10.04