30
Implementation and Configuration INSYS WLAN serial
The connection is automatically established when Telnet is selected in the menu
“Interface”. The IP address as well as the user name and the correct password of the
device to be configured must be entered in advance.
6.2 Configuration Via Terminal Program
The configuration of the INSYS WLAN serial can be performed directly by entering AT
commands in a terminal program.
6.2.1 AT Commands for Default Settings
Command Description
AT&F
Loading the default factory settings
AT&V
Display settings
AT&W
Saving the settings as user defaults
ATZ
Software reset and loading the user defaults
In Chapter 7 you will find a complete description of the AT commands and their
parameters.
6.2.2 Serial Interface
Control/PC and the INSYS WLAN serial must be modulated via the following joint
settings of the serial interface:
•
Baud rate (Data transmission speed)
•
Data format (data bits, parity, stop bits)
•
Data flow control (hardware handshake)
These settings must also be performed at the device which is connected to the INSYS
WLAN serial.
version 1.01 / 10.04