Page 6
Section 5
-
Installation
05/20 E&OE
Note –
when working with the unit, supply services when connected could reach 85°C, and once elec-
trically connected the station has 230V present within.
5.1
Location
The unit is designed for wall mounting. The unit can be mounted using either a wall bracket or spacer
hanging bracket [see Fig 5]. The spacer hanging bracket provides space to run pipes behind the unit if
required.
MOUNTING BRACKET
SPACER HANGING BRACKET
5.2
Pipework Connections
The
‘
district
’
and apartment pipework should be connected to the appropriate points labelled on the drawing in
Section 3 Dimensions. It is advisable to provide means of isolation and disconnection [via unions] on all
connections to the unit to facilitate replacement of the unit if this is ever required. Inta only recommend using
Inta dedicated connections kits as tabled below. You need to ensure that the systems you are connecting to, are
clean or have been flushed out appropriately.
ACCESSORIES for HIUV3
-
40 SINGLE PLATE HIU range
60mm Stand
-
off Brackets
ALV3ACBKT60
PACK OF 4 SECONDARY BALL VALVES PACK, WRAS APPROVED
HIAC03BVPACK
HIUV3 qty 1/2" MF Ballvalve Pack
ALV3BV
-
V3 DIRECT