© Intatec Ltd 2016
10
Re-Calibration
The factory setting at 41˚C can be altered to suit site conditions.
Warning: Care must be taken when altering the setting as incorrect calibration can cause injury.
• Remove the grub screw.
• Lift the handle cover off.
• Re-calibrate by removing the temperature stop rings from the cartridge and set the mixed water
to the required temperature by temporarily re-fitting the control lever.
• Once the required temperature is achieved replace the two temperature stop rings on the
splined spindle of the cartridge as shown. These two rings are used to prevent the temperature
of the cartridge from being altered whilst in use. The stop rings should be locked at either end
of the operating cycle and will form a physical stop to prevent the cartridge turning (see
below)
• Refit the lever assembly and grub screw.
• Recheck the calibrated temperature
A
B
A
A
B
B
Remove rings and
set water temperature
Replace rings
as shown
Rings act
as stops
Cartridge removal
1 Unscrew the retaining screw and remove the lever.
2 The thermostatic cartridge is a single piece construction and should be unscrewed
anti-clockwise from the mixer body using a suitably sized spanner.
3 When re-installing the cartridge into the mixer body, it should be tightened to a maximum
torque of 15 Nm