2
Technical Data
Power specification: 9V low voltage system
Power source - IR120CP:
6 x 1.5V AA batteries
IR121CP:
240V conversion kit
Recommended water pressure: 1.0 to 8.0 bar (14.5 to 116 psi)
With water pressure in excess of 8 bar use
with a pressure reducing valve.
Preset sensor range: 220 mm adjustment
Minimum sensor range: 80 mm
Maximum sensor range: 300 mm
Security time: 90 seconds
Hot water temperature: 70˚ C maximum - To limit the outlet
temperature to 41˚C max. we recommend
using theIntamix Thermostatic Mixing Valve
code 40015CP.
Pre-installation Information
Warning
Do not install the tap facing a mirror or any other electronic system operated by an infra red
sensor.
This tap is also vulnerable to stray sensor readings from users wearing high visibility or other
reflective clothing.
To prevent reflection problems, it is recommended to keep a minimum distance of 1.5m
between the tap and other objects.
Preparation for installation
Flush the water supply pipes thoroughly prior to installation. Do not allow debris, PTFE tape or
any metal particles to enter the tap.
Turn off the water supply.
Important:
All plumbing is to be installed in accordance with applicable codes and
regulations.
Installation
Step 1 - Preparation for mounting the tap
1. Shut off the water supply and remove the retaining nut and
washer from the threaded inlet.
Step 2 - Installing the tap
1. Ensure the ‘O’ ring and rubber washer are positioned on the
threaded inlet and located in the recess in the base of the tap.
2. Position the tap into the hole in the basin or water proof work
surface ensuring the ‘O’ ring is seated correctly.
3. Slide the washer and retaining nut over the flexible hose.
‘O’ ring
Rubber
washer
Retaining
nut
Washer