background image

© Intatec Ltd. 2006

5

B

Ba

atttteerryy RReep

plla

acceem

meenntt

((B

Ba

atttteerryy m

mo

od

deell o

onnllyy)) 

When the battery starts to runout, the red indicator light will flash at a constant rate. 

The battery must be replaced within two weeks. 

Release the screw at the bottom of the cover plate and remove the cover plate. 

Remove the screws and the protective cover of the battery housing from the sensor unit.

Replace the used battery with a new 9V battery, a Lithium battery is recommended. 

Refit the protective cover and wall plate. 

M

Ma

aiinntteenna

annccee

C

Ca

arree a

annd

d cclleea

anniinng

g o

off cchhrro

om

mee a

annd

d ssp

peecciia

all ffiinniisshheess

D

DO

O N

NO

OTT use steel wool or cleansing agents containing alcohol, acid, abrasives, or similar chemicals. 

The use of any prohibited cleaning or maintenance products could damage the surface of the flush 
valve. 

For surface cleaning, use only sso

oa

ap

p (mild washing-up liquid) and w

wa

atteerr, then wipe dry with a clean cloth 

or towel.

When cleaning wall tile, the flush valve should be protected against any splashing of harsh cleansers.

S

Sp

pa

arree PPa

arrttss LLiisstt

C

Co

om

mp

po

onneenntt

PPa

arrtt N

Nuum

mb

beerr

1.

Sensor Kit for IR230C

07220028

2.

Sensor Kit for IR231C

07220029

3.

Panel Kit

07040102

4.

Piston Kit

07290001

5.

Solenoid Valve Kit

07230005

6.

Push Button Kit

07245002

Optional accessories

7.

Remote control

IR303

For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk

Summary of Contents for IR230CP

Page 1: ...he information as accurate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further devel...

Page 2: ...t with the contents list Enure all parts are present before discarding any packaging If any parts are missing do not attempt to install your Inta electronic flush valve until the missing parts have be...

Page 3: ...o be isolated should servicing be required in the future Ensure that the water supply is isolated before commencing work Cut an adequate opening into the wall to accommodate the dimensions of the box...

Page 4: ...is too short i e not sensing users or too long i e sensing the opposite wall it may be adjusted as follows Disconnect the battery or switch off the electricity supply to the sensor For the IR230CP mak...

Page 5: ...remote control buttons R Ra an ng ge e The detection range is the greatest distance a person can be located to activate the sensor and is preset at the factory Press to increase and to decrease the de...

Page 6: ...f fi in ni is sh he es s D DO O N NO OT T use steel wool or cleansing agents containing alcohol acid abrasives or similar chemicals The use of any prohibited cleaning or maintenance products could da...

Page 7: ...Low Battery Replace battery Red light in the sensor does not flash when user steps within the sensor s range Range is too short Increase range Range is too long Decrease range Battery is completely u...

Reviews: