© Intatec Ltd. 2006
07-06
IInntta
atteecc LLttd
d
Airfield Industrial Estate
Hixon
Staffordshire
ST18 0PF
Tel: 0
01
18
88
89
9 2
20
07
72
20
00
0
Fax: 0
01
18
88
89
9 2
27
71
11
17
72
2
email: ssa
alleess@
@iinntta
acco
o..cco
o..uukk
web: w
ww
ww
w..iinntta
acco
o..cco
o..uukk
LLiim
miitteed
d W
Wa
arrrra
annttyy
This product is covered by a limited warranty for one year from date
of purchase.
During this period, Intatec Ltd undertakes, at its option, to repair or
replace any faults caused by defective materials or manufacturer that
may arise.
The guarantee does not cover faults or damage caused by incorrect
installation and/or maintenance, wear and tear, battery and water
deposits or leakage. This includes, but is not limited to the following:
Incorrect installation, inversions of supply pipes.
Pressures or temperatures exceeding the recommended limits.
Improper manipulation, tampering, bad or lapsed maintenance.
Foreign bodies, dirt or scale introduced by the water supply.
TTrro
ouub
bllee S
Shho
oo
ottiinng
g
Problem
Indicator
Cause
Solution
Valve does not flush
Sensor flashes continuously
when the user steps within the
senor’s range
Low Battery
Replace battery
Red light in the sensor does not
flash when user steps within the
sensor’s range
Range is too short
Increase range
Range is too long
Decrease range
Battery is completely used up
Replace battery
Sensor is picking up reflections
from mirror or other object.
Remove cause of reflection
Red light in the sensor flashes
when the user steps within the
sensor’s range
Cables between the electronic
unit and solenoid are
disconnected
Re-connect the electronic unit to
the solenoid valve
Debris or scale in solenoid
Unscrew the solenoid, pull out
the plunger and the spring from
the solenoid and clean them.
Use de-scaler solution if required
When replacing the plunger,
ensure the spring is vertical.
The water pressure is higher
than 8 bar
Reduce the supply water
pressure
Valve does not shut off Sensor flashes when the user
steps within the sensor’s range
Debris or scale in piston
Clean the piston and orifice
Red light in the sensor does not
flash when the user steps within
the sensor’s range
Sensor is dirty or covered #
Clean or remove cause of
interference
Sensor is picking up reflections
from mirror or another object
Decrease the range or remove
the cause of the reflection
# Water flow will stop after 90 seconds because of security time.