Check Contents

                                                            

Technical Data

 

   Power specification:                                           6V low voltage system

 

   Power source -                                                   IR500CP:

4 x 1.5V CRP2 batteries 

                                                                          IR501CP:

230V transformer  

   Operating water pressure:                                  1.0 to 8.0 bar (14.5 to 116 psi) 

                                                                          With water pressure in excess of 8 bar use 
                                                                          with a pressure reducing valve. 

   Max. recommended water pressure:                     5.0 bar 
   Hot water temperature:                                       5 to 65˚C maximum - To limit the outlet 

                                                                          temperature to 41˚C max. we recommend 
                                                                          using the Intamix Thermostatic Mixing Valve 
                                                                          code 40015CP. 

   Self opening after last water flow:                        Every 24 hours 

4 x 1,5V (AA)

Alkaline

10

To electricity
su

pp

ly

Transformer

230 V

Summary of Contents for IR500CP

Page 1: ...s possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise Intatec...

Page 2: ...r IR501CP Check Contents Before commencing remove all components from packaging and check each component with the contents list Ensure all parts are present before discarding any packaging If any part...

Page 3: ...ar 14 5 to 116 psi With water pressure in excess of 8 bar use with a pressure reducing valve Max recommended water pressure 5 0 bar Hot water temperature 5 to 65 C maximum To limit the outlet temperat...

Page 4: ...ed to keep a minimum distance of 1 5m between the tap and other objects Preparation for installation Flush the water supply pipes thoroughly prior to installation Do not allow debris PTFE tape or any...

Page 5: ...sensor window is clean and that there are no obstructions in front of the window 2 Insert batteries into the battery box or connect the transformer to electricity supply 3 Connect the power supply to...

Page 6: ...s which could damage the solenoid valve For this reason the inlet to solenoid valve has a gasket with an integral filter which must be kept clean in order to ensure a suitable water flow CAUTION turn...

Page 7: ...ilter Blocked solenoid valve Assistance required The water flows for 1 minute without an object in front of the sensor Dirty sensor Clean the sensor window Light reflections on the sensor Remove the r...

Page 8: ...on Staffordshire ST18 0PF Tel 01889 272 180 Fax 01889 272 181 email sales intatec co uk web www intatec co uk E O E 23 10 10 To active your product warranty please visit www intatec co uk and click on...