Introduction 

    This installation guide has been produced for the Nulo shower mixing valve. These instructions 
    cover the installation, operation and maintenance. Please read the enclosed instructions before
    commencing the installation of this product, please note;

   We recommend that the installation of any Inta product is carried out 
   by an approved installer.

    The installation must be carried out strictly in accordance with the Water Supply (Water Fitting)
    Regulations 1999 and any local authority regulations.

    If in doubt we recommend that you contact WRAS - Water Regulations Advisory Scheme on 
    Tel: 0333 207 9030, your local water authority - details available on the WRAS website or 
    the Chartered Institute of Plumbing and Heating Engineers on Tel: 01708 472 791.

    All products MUST be re-commissioned to suit site conditions to ensure optimum performance 
    levels of the product are obtained

Safety

This thermostatic shower must be installed and commissioned correctly to ensure that water is 
supplied at a safe temperature to suit the users. 

The shower is pre-set using ideal conditions to 38°C at the stop with a manual push button 
override to 46°C (can be re-set to suit site conditions or user preference – see calibration 
page 7). 

The maximum mixed temperature takes account of the allowable tolerances inherent in 
thermostatic shower mixers and temperature losses. 

It is not a safe bathing temperature for adults or children

.

The British Burns Association recommends 37 to 37.5˚C as a comfortable bathing 
temperature for children. In premises covered by the Care Standard Act 2000, the maximum 
mixed water outlet temperature is 43˚C.

Products

Nulo Thermostatic Bar Shower with Telescopic Riser, Overhead 
Soaker and Handset.

CB10032CP

Nulo Deluxe Safe Touch Thermostatic Bar Shower with Riser, Large 
Stainless Steel Soaker, Push Button Handset and Smooth Hose

CB10036CP

Nulo Thermostatic Bar Shower - valve only

ED10046CP

Check Content

    Before commencing remove all components from packaging and check each component with 
    the contents list. 

    Ensure all parts are present, before discarding any packaging. If any parts are missing, do not
    attempt to install your Inta shower valve until the missing parts have been obtained.

Summary of Contents for Nulo CB10032CP

Page 1: ...tion as accurate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or...

Page 2: ...d at a safe temperature to suit the users The shower is pre set using ideal conditions to 38 C at the stop with a manual push button override to 46 C can be re set to suit site conditions or user pref...

Page 3: ...t Temperature 85 C Max Inlet Pressure Dynamic 5 bar Pre Set Factory Temp Setting 38 C Min Operating Pressure Dynamic 0 4 bar Temperature Stability 2 C Max Unbalanced Pressure Ratio 5 1 Min Temp Differ...

Page 4: ...her than the hot supply we recommend that a separate pressure reducing valve is fitted to the cold supply as close as possible to the shower valve and with no draw off points between it and the shower...

Page 5: ...lt the pump manufacturer s installation requirements Gravity System The drawing shows a typical installation of a shower valve on a gravity supplied system Please note the minimum head pressure requir...

Page 6: ...plaster or plaster board should all be considered when routing the hot and cold supply pipes The valve requires the supply pipes and wall brackets to have 150mm centres and sufficient copper pipe mus...

Page 7: ...inside edge of the concealing plates position over the compression faces and press firmly to the wall Installing the Shower Valve The connector 10 check valve 9 filter 8 sealing washer 6 and union nu...

Page 8: ...ow control 1 and allow the outlet temperature to stabilise from the bottom outlet Temporarily refit the control knob bush 8 and control knob 6 and using a digital thermometer it is possible to increas...

Page 9: ...have a high quality finish and should be treated with care An occasional wipe with a mild washing up liquid on a soft damp cloth followed by a thorough rinsing is all that is required The nozzles in t...

Page 10: ...maximum showering temperature is too hot or when set to hot water runs to cold Check the commissioned maximum temperature of the shower valve Check the connections to the valve have not been made in r...

Page 11: ...Intatec Ltd 2017 10 NOTE drawing for illustration purposes only CB10032CP Fixed Riser Rail Dimensions 150 Ctrs 264 722 to 952 55 410 71 200...

Page 12: ...0 Item Qty Component 1 1 Riser rail 2 1 Riser rail grub screw 3 1 Handset holder 4 1 Adjustment bracket 5 4 Bracket grub screw 6 1 Adjustment piece 7 1 Wall bracket 8 2 Wall bracket grub screw 9 1 Ove...

Page 13: ...Intatec Ltd 2017 12 CB10036CP Deluxe Fixed Riser Rail Dimensions NOTE drawing for illustration purposes only 150 Ctrs 264 55 410 250 722 to 952...

Page 14: ...m Qty Component 1 1 Riser rail 2 1 Riser rail grub screw 3 1 Handset holder 4 1 Adjustment bracket 5 4 Bracket grub screw 6 1 Adjustment piece 7 1 Wall bracket 8 2 Wall bracket grub screw 9 1 Over hea...

Page 15: ...ithin the markings and using the hole as a template drill a 6mm diameter hole If drilling into ceramic tiles use a ceramic bit To avoid cracking ensure the wall plug is pushed all the way behind the c...

Page 16: ...ure the conditions of use are appropriate for the valve Introduction The thermostatic shower valve has been specifically designed and manufactured to meet the requirements of BS EN1111 1999 and TMV2 T...

Page 17: ...99 and also be aware of their responsibility and duty of care to ensure that all aspects of the installation comply with the regulations It has been brought to our attention that flushing water system...

Page 18: ...e s to within the limits as quoted previously 8 Any thermostatic shower valve must be fitted with a back flow prevention device such as check valves to prevent the cross contamination of supplies The...

Page 19: ...eratures are established before any attempt to commission 4 Once the supply temperatures are stable and the normal operating conditions are established the shower valve can be commissioned The followi...

Page 20: ...g performance checks shall be carried out 1 Measure the mixed water temperature at the outlet 2 Carry out the cold water supply isolation test by isolating the cold water supply wait for five seconds...

Page 21: ...Intatec Ltd 2017 20 Notes...