intarblock | intartop
35
Code
Description
Range
Default
List
MT
BT
nPS
Pressure switch activation number
0 ÷ 15
10
Pr2
ANALOGUE INPUTS
Ot
Thermostat probe calibration
-12,0 ÷ 12,0
ºC
0
Pr1
OE
Evaporator probe
-12,0 ÷ 12,0
ºC
0
Pr2
O3
Condenser probe calibration
-12,0 ÷ 12,0
ºC
0
Pr2
P2P
Evaporator probe presence:
n=no (defrosting by time) ; y=sí (desescarche por tiempo y Tª)
n - y
y
Pr2
P3P
Condenser probe presence: n=no ; y=yesí
n - y
y
Pr2
HE
S
Temperature increase during the Energy Saving cycle
-30,0 ÷ 30,0
ºC
2 ºC
Pr2
DIGITAL INPUTS
odc
When door is open, switches off the compressor (CPr), fan (Fan),
both (F_C), or non of them (no)
no, Fan, CPr,
F_C
F_C
Pr2
I1P
Door micriswitch polrity. CL=Closed; OP=Opened
CL - OP
OP
Pr2
I2P
Pressure switches polarity: CL=Closed; OP=Opened
CL - OP
OP
Pr2
I2F
Digital input 2 configuration: PAL=Pressure switches.
EAL, bAL,
PAL, dFr,
AUS, Es, onF
PAL
Pr2
did
Digital input alarm relay
0 ÷ 255 min
60
Pr2
oP2
External alarm polarity: cL=closed ; oP=Opened.
cL - oP
cL
Pr2
OTHERS
Adr
Serial address.
1 ÷ 247
1
Pr1
rEL
Software release
solo lectura
8.4
Pr2
Ptb
Dixell map code.
solo lectura
2
Pr2
Prd
Probe display values: thermostat “Pb1”, evaporator “Pb2” and
condenser “Pb3”.
Pb1, Pb2, Pb3
solo lectura
Pr2
Pr2
Access Pr2 parameter list.
Pr1
Configurable digital input
The unit has two digital inputs. One of them is always configured as a door switch. The other one is
preset as a pressure switch (
PAL
value assigned to parameter
“I2F”
). If during the interval time set by
“did”
parameter, the pressure switch has reached the number of activation of the
“nPS”
parameter,
the
“PAL”
pressure alarm message will be displayed. When the digital input is
ON
the compressor is
always
OFF
.
The digital inputs polarity depends on
“I1P”
and
“I2P”
parameters:
CL
indicates the digital input is
activated by closing the contact;
OP
indicates the digital input is activated by opening the contact.