Page 07
Controlvoltage(mV)=160(mV)xtestgasconcentrationCO(ppm)+40(mV)
measuringrangeCO(ppm)
Controlvoltage(mV)=200(mV)xtestgasconcentrationCO(ppm)
measuringrangeCO(ppm)
Measuringrange
250ppm
Testgasconcentration
200ppmCO
Controlvoltage:Signalstart2V/4mA
168mV
Controlvoltage:Signalstart0V/0mA
160mV
160(mV)x200(ppm)+40(mV)=168mV 200(mV)x200(ppm)=160mV
250(ppm) 250(ppm)