LGC/LG2-04
PolyGard
®
Multi-Point Controller
User Manual - LGC/LG2-04
Page 22
4.2 Unit position – Connection diagram
1 2
Digital
Inputs
Analog
Outputs
INTEC Controls
10.24 .13 10: 28am
Fault
Fault
Alarm
Alarm
1
X10
X11
X2
2
2 3 4 5 6
7 8 9 10 11 12 13 14 15
1
1 2 3 4 5 6 7 8 9 101112
1 2 3 4 5 6 7 8 9 101112
X1
Binary - Relay Outputs
R01
R03
R02
R04 R05
Sensor
Inputs
(see ill. 3)
24 VDC Input Power
(see ill. 1)
(see ill. 2)
(see ill. 4) (see ill. 5)
DIN Rail
Horn
X2
X1
3 4 5 6 7 8
1 2 3 4
1 2
(see ill. 6)
C5 Comm.
Coupler
Optional:
BACnet
ill. 1
1
(+)
Com
Terminal block
X1
24 VDC Input Power Supply
• “Min wire size 16 AWG (1.5 mm
2
)”
24 VDC, -15%/+20%, 50/60 Hz
2
ill. 6
1
8
7
6
5
4
3
2
X2
C5 BACnet Communication
Coupler, optional
RJ45
Upwards BACnet
communication
to BAS
Specifications subject to change without notice. | USA 131119 | Page 22 of 30
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
LGC-LG2 – UserManual
Polygard® is a registered trademark of MSR | LGC/LG2-04
Specifications subject to change without notice. | USA 160104 | Page 22 of 30
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.IN
TEC
| relevantsolutions.com/inteccontrols
LGC-LG2 – UserManual
PolyGard
®
is a registered trademark of MSR-Electronic GmbH | LGC/LG2-04
Specifications subject to change without notice. | USA 140924 | Page 5 of 6
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
FIELD WIRING CONFIGURATION
LGC-CO
1 2
Digital
Inputs
Analog
Outputs
INTEC Controls
10.24 .13 10: 28am
Fault
Fault
Alarm
Alarm
1
X10
X11
X2
2
2 3 4 5 6
7 8 9 10 11 12 13 14 15
1
1 2 3 4 5 6 7 8 9 101112
1 2 3 4 5 6 7 8 9 101112
X1
Binary - Relay Outputs
R01
R03
R02
R04 R05
Sensor
Inputs
(see ill. 3)
24 VD
C
Input Power
(see ill. 1)
(see ill. 2)
(see ill. 4) (see ill. 5)
DIN Rail
Horn
X2
X1
3 4 5 6 7 8
1 2 3 4
1 2
(see ill. 6)
C5 Comm.
Coupler
Optional:
BACnet
Recommended
• Twisted, shielded wire for analog inputs
(Shield to be terminated and connected only
at the sensor/transmitter location)
• Grounded housing
Caution:
The non-metallic enclosure does not provide
grounding between conduit connections. Use
grounding bushings and jumper wires.
The enclosure is to be mounted using the mounting
holes located in the base external to the equipment
cavity, or the equivalent.
The conduit hubs must be connected to the conduit
before connected to the enclosure.
When connecting conduit to the enclosure use only
UL Listed or UL Recognized conduit hubs that have
the same environmental type rating as the LGC-CO
enclosure.
ill. 1
1
(+)
Com
Terminal block
X1
24 VDC Input Power Supply
• “Min wire size 16 AWG (1.5 mm
2
)”
24 VDC, -15%/+20%, 50/60 Hz
2
ill. 6
1
8
7
6
5
4
3
2
X2
C5 BACnet Communication
Coupler, optional
RJ45
Upwards BACnet
communication
to BAS
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 200211 | Page 22 of 30
LGC-LG2 – UserManual