background image

 

Instruction Manual

 | 

14

 

 

T:  303-833-6644 

or

 800-666-1611 

www.inteccorp.com 

Original Language - English 

Chains

 

Removing the access panel provides access to the chain driving the two agitators.  The airlock chain is 
accessed thru the revolutionary tilt-back design. 
 
 
 
 
 
 
 
 

IQ

A

 Electrical Components 

Opening the electrical panel provides access to the electronics 
controlling your TURBO FORCE. 

 
 
 
 
 
IQ

A

 Filters 

Simply slide filter from holder, use compressed air or knock filter on a 
hard surface to remove contaminants, and replace filter in the 
appropriate holder on machine.   
 
 
 
 

IQ

A

 Slide Gate Settings 

Pull the pin, slide gate to recommended setting, and you are on your way 
towards obtaining appropriately conditioned insulation for the task at hand.   
 

 

Summary of Contents for TURBO FORCE HP2

Page 1: ...tion Manual Insulation blowing machine Original Language English Intec 4040 Kodiak Court Frederick CO 80504 USA T 303 833 6644 Web www inteccorp com Email info inteccorp com T 800 666 1611 Rev Date 20...

Page 2: ...es and installation versatility all of our durable systems are made to maximize your profit generating potential VORTEC VACUUMS Powered by Gas or Electric Engineered for High Productivity and Built to...

Page 3: ...glish Table of Contents INTRODUCTION 1 SYMBOLS 3 SAFETY FIRST 3 HOW THE SYSTEM WORKS 4 System Set Up 5 System Operation 6 TROUBLESHOOTING 15 SPECIFICATIONS 18 ELECTRICAL DRAWINGS 19 TURBO FORCE HP2 TU...

Page 4: ...te equipment with chain guard off Never operate equipment with hopper in tilt back mode Never operate equipment while standing in water as electrical shock may result Always use grounded extension cor...

Page 5: ...ading Platform The loading platform acts as a shelf to support the bag of insulation being loaded into the hopper Hopper The hopper contains the insulation being Filters Ensure clean air is being used...

Page 6: ...pin in desired opening Note suggested settings are labeled by slide gate 4 Connect 12 3 gauge heavy duty power cords each power source is required to be an independent circuit A 120Volt systems If ca...

Page 7: ...ure that circuit breaker is not tripped Reset if needed by pushing the circuit breaker back in c Pull out the Emergency Stop Button d Press the Power On button Power On button ring and Variable Speed...

Page 8: ...turn on Blower 1 Turning the Rotary Switch one more position to the right Blower Agitator will turn on the Agitator This is known as Panel Controlled a Blower 2 can now be turned on if desired by pre...

Page 9: ...Wired Remote Operations To utilize a wired remote on your system you will want to set the Rotary Control Switch to WIRED REMOTE and plug in the wired remote into the Remote Receptacle Please be aware...

Page 10: ...teps to Re Sync your Wireless Remote to your Receiver 1 System must be plugged in 2 Rotate Rotary Control Switch to Wireless Remote position Learn Button should have a steady blue flashing light 3 Pre...

Page 11: ...e system s handle Lift loading platform up swing loading platform down A Cellulose Set bag on platform remove plastic wrapping Be sure no plastic goes into hopper NOTE A1 Orientation of bag is importa...

Page 12: ...into hopper Keep plastic out of hopper NOTE B1 Orientation of bag is important to ensure smooth material processing and to limit product bridging from occuring Product bridging is when product is in...

Page 13: ...he airlock can cause damage and reduce the machine s production Seal failure is the most common airlock assembly failure Seal failure prevents the airlock from holding the proper pressure Seal failure...

Page 14: ...uired at times Making these activities as easy efficient as possible so you can get back up and running in the quickest of manners is why Intec Quick Access was developed IQA TM was designed to furthe...

Page 15: ...lectrical Components Opening the electrical panel provides access to the electronics controlling your TURBO FORCE IQA Filters Simply slide filter from holder use compressed air or knock filter on a ha...

Page 16: ...urnt out Attempt to run system Electrical system may have a loose wire Call Tech Support Blower 1 does not run Blower 1 circuit breaker may be tripped Reset Blower 1 circuit breaker Rotary Switch in w...

Page 17: ...f Turn blower on Air pocket in hopper is preventing insulation from feeding into agitators Disconnect electrical power Redistribute insulation material inside hopper Airlock seal is worn Inspect airlo...

Page 18: ...5amp separate circuit for agitator and each blower Extension cord gauge is too small Use a 12 3 heavy duty i e SJ300V extension cord with 115V Chain is not aligned with sprockets Disconnect electrical...

Page 19: ...a trailer or truck make sure the trailer or truck s doors especially the large door in back are open to allow for radio frequency waves to easily enter and access the receiver in the blowing machine...

Page 20: ...NA version EU Version TURBO FORCE HP MAX NA version EU Version HP 115VAC 7 1 amp 230VAC 4 5 amp HP 115VAC 9 5 amp 230VAC 5 9 amp Airlock Motor TURBO FORCE HP2 NA version EU Version TURBO FORCE HP MAX...

Page 21: ...Instruction Manual 19 T 303 833 6644 or 800 666 1611 www inteccorp com Original Language English Electrical Drawings TURBO FORCE HP2 TURBO FORCE HP MAX US TURBO FORCE HP2 TURBO FORCE MAX...

Page 22: ...ility It is the responsibility of the consignee to file a claim Proper documentation is necessary to support the claim Please inspect all items properly prior to signing for them 2 Items received not...

Page 23: ...rantied for a period of ninety 90 days from date of factory shipment c This Warranty shall not apply to any MACHINE or component part which in the opinion of the MANUFACTURER has been altered subject...

Page 24: ...Instruction Manual 23 T 303 833 6644 or 800 666 1611 www inteccorp com Original Language English Certifications...

Reviews: