4. UPS DESCRIPTION
This kind of equipment is known as UPS (Uninterruptible Power Supply). It has 2 main functions: give electrical
protection against surges, spikes and some other dangerous failures of electrical main system and also
provides electrical backup based on internal batteries. In that way products you connect to your UPS will be
protected and will receive electrical energy even during failures of main electrical AC system.
This UPS is designed to satisfy all requirements of Personal Computers (PCs). It includes internal voltage
regulator to stabilize input AC variations without using internal batteries. Only in presence of important input
failures UPS will use internal batteries to provide energy in outlet sockets. In this way batteries life expectancy is
longer.
1.- Output sockets
4.- RJ-11 protected sockets
2.- Input AC
5.- USB port
3.- Input breaker
6.- USB in 120V models could be optional
As mentioned this UPS will provide backup energy in its outlets when main AC input fails. Runtime will depend
on some different factors:
Battery charging level.
Battery capacity according to the use given and lifetime.
Load consumption connected to UPS outlets. Higher the output load shorter the runtime.
Under normal condition, when UPS is ON and connected to AC source, UPS will keep batteries fully charged.
WARNING:
This UPS is not compatible with power plants and generators. Do not connect this UPS to outlets supplied
by power plants / generators.
USER MANUAL -
EPLUS 501/701/901
ENGLISH
________________________________________________________
www.integra-ups.com 1303-EPLUS 501/701/901-ENG -
5
5. UPS INSTALLATION
This UPS must be installed indoor with controlled environment free of excessive dust, corrosive air or
conductive dust.
Do not install in outdoor. Keep UPS working under operational conditions listed in specifications table of
this manual. Keep out of direct sun light, water and heat sources.
Do not install UPS close to PC screen to avoid interference. UPS must be at least at 20cm from screen.
Connect TEL line to RJ11 port in this UPS identified as IN. Connect router input to RJ-11 port in this UPS
identified as OUT
Plug power cord of this UPS to AC source socket.
Plug your products to UPS outlets.
IMPORTANT WARNINGS:
Make sure UPS is plugged to AC source compatible with UPS electrical specifications. Check UPS specs
in UPS label.
Make sure your products input voltage is compatible with UPS voltage output.
Check total load in Watts to be connected to UPS is not higher to maximum UPS capacity.
Do NOT plug neither laser printers nor copiers to this UPS. This equipments are high load products will
overload your UPS.
6. UPS OPERATION
Once UPS is installed and connected according to section 4 of this manual, please turn UPS on by
ON/OFF button in front panel. Front panel green LED must turns ON.
Turn your products ON one by one.
After finishing your products will be fully protected by the UPS.
This UPS has COLD-START function that allows to turn UPS on even during a failure in the main AC source.
Front panel LED will let you know UPS status: OFF / ON / BATTERY MODE.