USER MANUAL 

EPRO RACK 1.1K-3.4K 

____________________________________________________________________________________________

 

(120217_ENG) Integra EPRO RACK 1.1K-3.4K

  

 - 

13

 

 

Power consumption 
(connected to UPS outlets)I 

 

Indicates power output supplied by UPS:
0-25%,  
26-50%,  
51-75% y 
76-100%.  

 

Indicates overload at UPS output. Devices connected in UPS outlets load 
UPS above UPS capacity. 

 

Indicates short circuit at UPS output.

Programmable Outputs 

 

Indicates programmable function is activated.

Operation Mode 

 

Indicates UPS is connected to input AC source under normal range..

 

Indicates UPS is in battery mode.

 

Indicates UPS is in BYPASS mode.

 

Indicates ECO Mode is active 

 

Indicates UPS inverter is running.

 

Indicates UPS outlets are powered.

Battery Information 

 

Indicates battery charging level: 
0-25%,  
26-50%,  
51-75% y 
76-100%. 

 

Indicates battery failure 

 

Indicates low battery level 

Input  Information 

 

Indicates input voltage, input frequency and DC battery voltage
Vac: Input voltage, Vdc: battery voltage, Hz: input frequency 

 
 

 

USER MANUAL 

EPRO RACK 1.1K-3.4K 

____________________________________________________________________________________________

 

(120217_ENG) Integra EPRO RACK 1.1K-3.4K

  

 - 

14

 

 
ACOSUTIC ALARM 

Battery Mode: 

 

1 “Beep” every 4 seconds 

Battery Low: 

 

1 “Beep” per second 

Output Overload: 

 

2 “Beeps” per second  

UPS Failure: 

 

Continuous Beep 

By-Pass Mode: 

 

1 Beep every 10 seconds. 

 

7. LCD TEXT MESSAGES 
 

TEXT LCD 

TEXT 

Meaning 

ENA 

 

Enable (Habilitado) 

DIS 

  

Disable (Des-habilitado) 

ESC 

 

Escape (Salir) 

HLS 

 

High Limit for Baypass (Límite Alto para 
Bypass) 

LLS 

 

Low Limit for Baypass (Límite Bajo para 
Bypass) 

BAT 

 

Battery (Batería) 

CF 

 

Converter (Convertidor de Frecuencia) 

EP 

 

EPO (Emergency Power Off) 

FA 

 

Fan (Ventilador) 

TP 

 

Temperature (Temperatura) 

CH 

 

Charger (Cargador de Baterías) 

 
 

Summary of Contents for EPRO-RACK 1.1KVA

Page 1: ...ntilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect this UPS to any of its o...

Page 2: ...2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electroma...

Page 3: ...OWER ON Keep selected during 2 seconds or longer b BEEP MUTE In battery mode Keep selected during 5 seconds or longer to Mute acoustic alarm beep Some alarms cannot be muted as Bypass Warning or ERROR...

Page 4: ..._______________________________________________________ 120217_ENG Integra EPRO RACK 1 1K 3 4K 8 3 2 RACK UPS INSTALLATION Rack UPS must be installed using L Shape type guides for supporting UPS weigh...

Page 5: ...models but they can also be connected at any moment to EX BATT supplied by INTEGRA Special cables to connect EX BATT to UPS are supplied inside the box of EX BATT USER MANUAL EPRO RACK 1 1K 3 4K _____...

Page 6: ...power from batteries There is no dead time transition time is ZERO ms related to switching from normal mode to battery mode since load is always powered from inverter This is main characteristic of an...

Page 7: ...charging level 0 25 26 50 51 75 y 76 100 Indicates battery failure Indicates low battery level Input Information Indicates input voltage input frequency and DC battery voltage Vac Input voltage Vdc b...

Page 8: ...ts To able or disable programmable outlets function 09 Programmable To configure timer value in minutes for programmable outlets USER MANUAL EPRO RACK 1 1K 3 4K _______________________________________...

Page 9: ...as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries USER MANUAL EPRO RACK 1 1K 3 4K ______________________________...

Page 10: ...selected properly Push ON button during 2 seconds or longer 1 beep s alarm is active and LCD shows Input Line and Neutral are swapped Rotate UPS plug at wall socket to allow correct line neutral conne...

Page 11: ...igurable scheduled shutdown and Auto tests Some UPS models include software CD inside the box Others allow software downloaded from our website www integra ups com 14 BATTERIES MAINTENANCE 14 1 BATTER...

Page 12: ...teries Kit 1 Remove batteries from plastic assembly 2 Connect new batteries in series as indicated below 3 Place batteries inside plastic assembly 4 Close battery assembly 5 Using a DVM check battery...

Page 13: ...al service caused by improper packing of the product by user 12 Warranty time could be extended to 3 years depending on market or products Contact your authorized dealer for additional information 13...

Reviews: