USER MANUAL - OPTIMA RT10 1K/1.5K/2K/3K (UL) 

www.xmart-ups.com 

VER.2010.22-One (ENG)

25 

15. SPECIFICATIONS (1/2)

Capacity / Capacidad 
Output PF / FP de Salida
Capacity / Capacidad 
Output PF / FP de Salida

INPUT / ENTRADA

Range / Rango - Vac

120V (UL)

Range / Rango - Vac

220V/230V

Frequency Range / Rango de Frecuencia
Max. Amps / Corriente Max.

(normal mode) (120V UL)

Max. Amps / Corriente Max.

(normal mode) (230V)

OUTPUT / SALIDA

Voltage / Voltaje AC

(120V UL)

Voltage / Voltaje AC

(220V/230V)

Output Regulation / Rango de Salida:

Slew Rate / Seguimiento de Frecuencia

BYPASS

Internal Auto bypass / Modo Bypass Automático:

PROTECTION SYSTEMS / SISTEMAS DE PROTECCION

Surge & Spikes Suppression / Supresión de Picos
RJ45 Surge Suppression / Supresión picos RJ45

AC Input Current  / Sobre-Corriente de Entrada AC

Starting Time / Tiempo de Arranque (@ 100% load)

EFFICIENCY / EFICIENCIA

Eco Mode

Inverter Efficiency / Eficiencia Inversor (100%)
Max. Internal Loss / Pérdidas internas máx. (BTU)

OVERLOAD/ SOBRECARGA

AC Mode / Modo Normal (to Bypass)
Battery Mode / Modo Batería (to OFF)
Bypass Mode / Modo Bypass (to OFF)

BATTERIES / BATERIAS

Technology / Tecnología
Qty & Type / Cantidad&Tipo
Charging VDC / Voltaje del cargador (Floating)
Typical Recharge Time / T. de Recarga
Shutdown battery Voltage / Voltaje DC Apagado
Charging Amps / Corriente de Carga
Batteries charger / Cargador de baterías
Charging Compensation /Compensación Recarga
Recharging Time / Tiempo de recarga (90%)

2 x 12V-9AH

3 x 12V-9AH

4 x 12V-9AH

(100% LOAD: 97%)

YUASA or CSB: Sealed Lead Acid VRLA-AGM / Sellada Sin Mantenimiento VRLA-AGM

>30ºC : -5mV/ºC per cell (Equalization) / -3mV per cell (Floating)

1.00

 (160Vac-300Vac) @ 100% load  /  (140Vac-300Vac) @ 80% load  /  (110Vac-300Vac) @ 60% load 

7.6A (RMS)

11.0A (RMS)

15.3A (RMS)

17.6A (RMS)

100%~110%: (warning) /  110%~120%: 30min / 120%~130%: 10min / LOAD >130%: 1min

100%~110%: (warning) /  110%~130%: 5min / 130%~140%: 30s

100%~110%: (warning) /  110%~130%: 5min / 130%~140%: 30s  / >140%: 2s

(100% LOAD: 

>

9

8

%)  -  (75% LOAD: 

>

9

7

%)  -  (50% LOAD: 

>

96%)  -  (25% LOAD: 

>

9

5

%)

(100% LOAD: 91%)  -  (75% LOAD: 91%)  -  (50% LOAD: 90%)  -  (25% LOAD: 89%)

AC Mode / Modo AC (Online)

(100% LOAD: 90%)  -  (75% LOAD: 90%)  -  (50% LOAD: 89%)  -  (25% LOAD: 88%)

40 Hz - 70Hz

0 ms

> 0.99 @ 100% load

(L-N, L-G, N-G) :   > 1370 Joules (EN61000-4-5)

Electronic inverter shortcircuit protection / Protección contra cortocircuitos en la salida

Triggered by output current over 400% of nominal current during 5 cycles / 

Activación a 400% de la corriente nominal durante 5 ciclos

3:1 max. @ 100% load

460

546

30ms (up to 90% of regulation) / 60ms (up to 100% regulation) (variation 0%-100% or 100%-0%)

 (80Vac-150Vac) @ 100% load  /  (70Vac-150Vac) @ 80% load  /  (55Vac-150Vac) @ 60% load 

1.00

0.97

0.96

307

818

1000VA / 1000W

1500VA / 1500W

2000VA / 2000W

ONLINE RT10 1K - 3K

1K

1.5K

2K

3K

13.2A (RMS)

13.2A (RMS)

17.6A (RMS)

220V/230V

3000VA / 3000W

 50Hz / 60Hz autosensing / detección automática 

26.4A (RMS)

1000VA / 1000W

1500VA / 1450W

2000VA / 1930W

3000VA / 2880W

0.97

1.00

1.00

1.00

Harmonic Distortion / Dist. Armónica (THDv)

< 2% @ Linear Load / Carga Lineal (100% load)

<4% @ No Linear Load / Carga no Lineal (100% load)

AC to Inverter / Modo Online a modo Batery

120V (UL)

Phase / Fases

Single phase with ground / (L, N, G)

Power Factor / Factor de Potencia
Input Current THDi / THDi de Corriente de Entrada

< 5% @ 100% load

Frequency Input / Frecuencia de Entrada

1 Hz / s

(*N1) Model 120V: 100/110/115/120/127Vac

  +/-1% (all modes / en todos los modos de operación)

Frequency / Frecuencia (Batt. Mode)

(*N3) 50 Hz +/- 0.1 Hz     -     60Hz +/- 0.1 Hz

Current Crest Ratio / Factor de Cresta

(*N1) Model 120V: 200/208/220/230/240Vac

Transient response / Respuesta ante Carga Variable

Waveform / Forma de Onda

Pure Sinewave / Sinusoidal Pura

Battery Mode / Modo Batería

Fuse protection for battery line / Protección por fusible en línea interna de baterías (80A)

Input breaker or fuse / Disyuntor o fusible de entrada

Battery overcurrent / Sobrecorriente de baterías

DC component / Componente DC

100mV max. (no load / full load)  (EN50091-3)

IN/OUT RJ45 socket surge protected / Tomas RJ45 protegidas contra picos

Configurable 2A to 8A. // (0.1C min / 0.2C recommended / 0.3C max.)

54.7 VDC +/-1% 

82.1 VDC +/-1% 

4 Hours for 90% capacity / 4 Horas para recuperar el 90% de carga

27.4 VDC +/- 1% 

41.1 VDC +/- 1% 

Default Input Range in BYPASS: (120V): 85-132Vac   //   (230V): 170-264Vac   (Configurable)

7s - 10s

6 x 12V-9AH

Dynamic Accuracy / Regulación Carga Variable

< +/- 5% in Online (variation 0%-100% & 100%-0% R Load) (online mode)

10.0 Vdc per battery typical (*N4)

Output Short-Circuits / Cortocircuitos a la Salida
(Online & Battery Mode)

2h - 3h (*N5)

3 steps technology / Tecnología de 3 etapas (Constant Current / Equalizing / Floating)

Summary of Contents for Xmart OPTIMA RT10 1.5K

Page 1: ...n on this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products...

Page 2: ...STRUCTIONS 2 PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTI...

Page 3: ...ge the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the UPS based on inrush current instead of average current Inrush current typical of motor based sys...

Page 4: ...NG Modifications made on the product or the use of this product as a part of a more complex system not expressly approved by the party responsible for compliance could void the user s authority to ope...

Page 5: ...d only by these handles 1 Install black handles to the UPS 2 Make sure rack cabinet counts with required mounting guides 3 Place UPS on the guides and fix it to the cabinet using black handles VERTICA...

Page 6: ...connected to this UPS to have longer runtime External batteries are optional for long run applications XBAT must be connected by using original DC cables included inside XBAT box XBAT must be connect...

Page 7: ...Bypass mode is adopted in case ON button has not been activated as soon as UPS detects a valid AC input on its terminals If bypass mode is not enabled UPS will simply light its LCD Outputs will keep p...

Page 8: ...ut UPS output is generated by inverter BATTERY MODE A Input indicator at bottom left corner A shows Battery voltage since there is no valid AC input detected B Output indicator displays AC output gene...

Page 9: ...f test performs a full checking of systems and batteries OFF ENTER UPS TURN OFF Press for 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALU...

Page 10: ...NPUT INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also...

Page 11: ...mable output powered 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the U...

Page 12: ...ODE ON MUTE Used as key to navigate or changing parameters value OFF ENTER Used as ENTER key to confirm modifications SELECT Used as key to navigate or changing parameters value CONFIGURATION MENU For...

Page 13: ...of nominal voltage Factory set 6Vac Set values with keys 06 BYPASS ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS 07 BYPASS INPUT VOLTAGE RANGE Set values with keys Valid input VOLTAGE range fo...

Page 14: ...TTERY CHARGER CURRENT Sets recharging current in Amps 1 2 4 6 or 8 A 14 BOOSTING CHARGING VOLTAGE NO MODIFICATIONS RECOMMENDED ONLY FOR TECHNICIANS Charging voltage can be increased Adjustable Voltage...

Page 15: ...Active Open AC Active Close BAH Battery AH BAT Battery BR Battery Replacement CBV Charger Boost Voltage CFV Charger Float Voltage CF Frequency Converter Function CHA Charger current CH Charger Batter...

Page 16: ...symbols and codes with intermittent beeps Tipo de ALARMA SIMBOLO INTERMITENTE ALARMA SONORA OVERLOAD UPS Load exceeds UPS capacity 1 beep s LOW BATTERY 1 beep 2s BATTERY FAULT 1 beep 2s BATTERY REPLA...

Page 17: ...the UPS TIPO DE FALLA CODIGO DE FALLA SIMBOLO BUS START FAIL 01 BUS OVER 02 BUS UNDER 03 INVERTER SOFT START FAIL 11 INVERTER VOLTAGE HIGH 12 INVERTER VOLTAGE LOW 13 INVERTER OUTPUT SHORT 14 BATT VOLT...

Page 18: ...tion and install the UPS again EEPROM Failure Turn off and power off UPS Restart UPS If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off UPS Discon...

Page 19: ...f UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged according to this plan batteries will get permanent damage This kind of damage is not covered by...

Page 20: ...MENT 3 BATTERIES 36VDC MODELS 1 5KVA 1 Remove old batteries 2 Connect 2 batteries in series 3 Install new batteries in the binder 4 Close binder BATTERY REPLACEMENT 4 BATTERIES 48VDC MODELS 2KVA 1 Rem...

Page 21: ...ry charger uses a 3 steps algorithm to care batteries 1 Constant Current During this stage charger injects a constant current meanwhile batteries increase their voltage During this stage batteries rec...

Page 22: ...ribution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is...

Page 23: ...C SELECT 6 Emergency power off connector port D OFF ENTER 7 USB RS232 ports 1 Standard UPS outlets 8 Intelligent SNMP port 2 Programmable outlets 9 External Battery connector optional in some models 3...

Page 24: ...INDEX USER MANUAL OPTIMA RT10 1K 1 5K 2K 3K UL www xmart ups com VER 2010 22 One ENG 24...

Page 25: ...5 Electronic inverter shortcircuit protection Protecci n contra cortocircuitos en la salida Triggered by output current over 400 of nominal current during 5 cycles Activaci n a 400 de la corriente no...

Page 26: ...alida es configurable entre 4 alternativas seleccionables en el LCD N2 Backup time for programable outlets can be configurable in minutes Las salidas programables pueden configurarse en minutos N3 All...

Page 27: ......

Page 28: ...USA Headquarters 10540 NW 26th St Doral FL 33172 USA EUROPE Headquarters Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain Latin America Headquarters Santiago de Chile 8330669 Chile CHILE...

Reviews: