INDEX

 

USER MANUAL - OPTIMA RT10 1K/1.5K/2K/3K (UL) 

 

 

www.xmart-ups.com 

VER.2010.22-One (ENG)

 

    

1.

 

GENERAL SAFETY INSTRUCTIONS 

 

WARNING

: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating 

this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults. 

UPS manufacturer or distributor will never be responsible for any accident produced by lack of knowledge or negligent practices at the 

moment of install, starting up or maintain this product. UPS manufacturer or distributor is not liable for any damage that might rise from 

misusing this unit or defective installation.  

 

 

ELECTRIC SHOCK RISK

 

This product operates with dangerous voltages. It must be installed, operated and maintained ONLY by qualified technicians trained for 

this kind of products. Service personnel MUST know and understand very well all electric risks related to this product. 

If you are not qualified technician do not try to install, operate or repair this product. 

CAUTION:

 There are dangerous voltages in the UPS power outlets although the equipment is not plugged to power line. 

CAUTION:

 Inside this equipment, due to internal batteries, there are ALWAYS dangerous voltages, EVEN the UPS is OFF and unplugged. 

CAUTION:

 There are dangerous voltages in internal DC Capacitors. Wait at least 10 minutes after turning off UPS before opening it to 

access inside. 

CAUTION:

 Power off UPS and unplugged it from AC Line before opening it to access inside this unit. 

CAUTION:

  Before  starting  the  opening  procedure,  remove  all  jewelry  and  metallic  objects  such  as:  Rings,  Watches,  Bracelets,  etc., 

because they could contact conductive parts and components inside the UPS and this might cause discharges and/or short circuits. 

Make sure using tools properly isolated to avoid electrical risks. 

WARNING:

 This product has been designed to be used indoors protected from water, direct sun light, dust and extreme temperature. 

WARNING:

 Do not put any object on the UPS; do not apply any force over UPS. Do not cover UPS ventilation. 

WARNING:

 This UPS must be connected to appropriate electrical service according to selected model. Technical specs label in the UPS 

shows the UPS power ratings. DO NOT connect this UPS to any of its own power outlets, this could damage the unit permanently. 

WARNING:

 Do not connect AC motor-based equipment without a careful sizing of the UPS based on inrush current instead of average 

current. Inrush current typical of motor-based system could overload this UPS. 

WARNING:

 In case of emergency, power-off UPS and turn it off by <OFF> button in front panel. Then call technical service. 

 

INFORMATION FOR THE PROTECTION OF ENVIROMENT 

 UPS SERVICING

 

This  UPS  and  batteries  make  use  of  components  dangerous  for  the  environment  (electronic  cards,  electronic  components).  The 

components removed must be taken to specialized collection and disposal centers. 

 

NOTICE TO EUROPEAN UNION CUSTOMERS: DISPOSAL OF OLD APPLIANCES 

This  product  has  been  supplied  from  an  environmentally  aware  manufacturer  that  complies  with  Waste  Electrical  and 

Electronic Equipment (WEEE) Directive 2002/96/CE. The “crossed

-

out wheelie bin” symbol a

t left is placed on this product to 

encourage you to recycle wherever possible. Please be environmentally responsible and recycle this product through your 

recycling facility at its end of life. Do not dispose of this product as unsorted municipal waste. Follow local municipal waste 

electrical and electronic equipment (WEEE). 

 

 

 

 

2.

 

PRODUCT DESCRIPTION 

 

This is an Uninterruptible Power Supply (UPS) ONLINE DOUBLE CONVERSION with IGBT technology at rectifier and inverter stages with 

PWM  modulation.  It  generates  a  pure  SINEWAVE  output  free  of  noise  and  imperfections  for  powering  and  protecting  your  valuable 

system. This UPS is the right choice to protect hardware and data in critical workstations and server applications. 

This  product  has  been  designed  to  operate  under  hostile  electrical  conditions  but  offering  a  reliable  performance  with  outstanding 

features and characteristics. Optima RT10 is equipped with a powerful anti-surge system based on MOV technology. This model has 

filtering circuits for EMI interferences. It is 100% compatible to operate connected to low quality AC sources like power generators. Soft-

start function allows connection to AC input source is done only when AC input values are confirmed inside operational ranges. 

Our  monitoring  software  allows  configuring  and  controlling  this  UPS  by  any  of  available  communications  ports:  USB/RS232  or  LAN 

Ethernet optional card (under SNMP protocol). 

 

 

OPTIMA RT10 series has 4 different models for supporting all kind of applications from 1KVA to 3KVA: 

 

Models 120V (UL): 

1.000VA/1.000W 

1.500VA/1.450W 

2.000VA/1.930W 

3.000VA/2.880W 

Models 220V-230V: 

1.000VA/1.000W 

1.500VA/1.500W 

2.000VA/2.000W 

3.000VA/3.000W 

 

 

 

Summary of Contents for Xmart OPTIMA RT10 1.5K

Page 1: ...n on this manual is property of XMART This manual Information cannot be copied or distributed totally or partially without written approval of XMART XMART can introduce modifications in their products...

Page 2: ...STRUCTIONS 2 PRODUCT DESCRIPTION 3 SAFETY QUALITY AND PERFORMANCE STANDARDS 4 INSTALLATION 5 OPERATION MODES 6 OPERATION INTERFACE KEYBOARD LCD 7 UPS CONFIGURATION 8 ERROR ALARMS CODES 9 TROUBLESHOOTI...

Page 3: ...ge the unit permanently WARNING Do not connect AC motor based equipment without a careful sizing of the UPS based on inrush current instead of average current Inrush current typical of motor based sys...

Page 4: ...NG Modifications made on the product or the use of this product as a part of a more complex system not expressly approved by the party responsible for compliance could void the user s authority to ope...

Page 5: ...d only by these handles 1 Install black handles to the UPS 2 Make sure rack cabinet counts with required mounting guides 3 Place UPS on the guides and fix it to the cabinet using black handles VERTICA...

Page 6: ...connected to this UPS to have longer runtime External batteries are optional for long run applications XBAT must be connected by using original DC cables included inside XBAT box XBAT must be connect...

Page 7: ...Bypass mode is adopted in case ON button has not been activated as soon as UPS detects a valid AC input on its terminals If bypass mode is not enabled UPS will simply light its LCD Outputs will keep p...

Page 8: ...ut UPS output is generated by inverter BATTERY MODE A Input indicator at bottom left corner A shows Battery voltage since there is no valid AC input detected B Output indicator displays AC output gene...

Page 9: ...f test performs a full checking of systems and batteries OFF ENTER UPS TURN OFF Press for 2 seconds to turn UPS off ENTER When UPS is in configuration mode this key operates as ENTER SELECT CHECK VALU...

Page 10: ...NPUT INFORMATION It displays AC output voltage Output frequency in Hz ALARMS ERRORS This section of the LCD displays active alarms and errors providing codes and descriptive symbols This section also...

Page 11: ...mable output powered 5 BYAPSS internal static line active 6 ECO mode active 7 Audible alarm beep muted OUTPUT POWER METER This area displays graphically by a 4 segments bar the power supplied by the U...

Page 12: ...ODE ON MUTE Used as key to navigate or changing parameters value OFF ENTER Used as ENTER key to confirm modifications SELECT Used as key to navigate or changing parameters value CONFIGURATION MENU For...

Page 13: ...of nominal voltage Factory set 6Vac Set values with keys 06 BYPASS ENABLE DISABLE ENA ENABLE DIS DISABLE Factory set DIS 07 BYPASS INPUT VOLTAGE RANGE Set values with keys Valid input VOLTAGE range fo...

Page 14: ...TTERY CHARGER CURRENT Sets recharging current in Amps 1 2 4 6 or 8 A 14 BOOSTING CHARGING VOLTAGE NO MODIFICATIONS RECOMMENDED ONLY FOR TECHNICIANS Charging voltage can be increased Adjustable Voltage...

Page 15: ...Active Open AC Active Close BAH Battery AH BAT Battery BR Battery Replacement CBV Charger Boost Voltage CFV Charger Float Voltage CF Frequency Converter Function CHA Charger current CH Charger Batter...

Page 16: ...symbols and codes with intermittent beeps Tipo de ALARMA SIMBOLO INTERMITENTE ALARMA SONORA OVERLOAD UPS Load exceeds UPS capacity 1 beep s LOW BATTERY 1 beep 2s BATTERY FAULT 1 beep 2s BATTERY REPLA...

Page 17: ...the UPS TIPO DE FALLA CODIGO DE FALLA SIMBOLO BUS START FAIL 01 BUS OVER 02 BUS UNDER 03 INVERTER SOFT START FAIL 11 INVERTER VOLTAGE HIGH 12 INVERTER VOLTAGE LOW 13 INVERTER OUTPUT SHORT 14 BATT VOLT...

Page 18: ...tion and install the UPS again EEPROM Failure Turn off and power off UPS Restart UPS If not solved call technical service ERROR CODES PROBABLE CAUSE SOLUCION 01 02 03 Turn off and power off UPS Discon...

Page 19: ...f UPS will be stored for long time it is mandatory to recharge UPS periodically If UPS is not recharged according to this plan batteries will get permanent damage This kind of damage is not covered by...

Page 20: ...MENT 3 BATTERIES 36VDC MODELS 1 5KVA 1 Remove old batteries 2 Connect 2 batteries in series 3 Install new batteries in the binder 4 Close binder BATTERY REPLACEMENT 4 BATTERIES 48VDC MODELS 2KVA 1 Rem...

Page 21: ...ry charger uses a 3 steps algorithm to care batteries 1 Constant Current During this stage charger injects a constant current meanwhile batteries increase their voltage During this stage batteries rec...

Page 22: ...ribution service partners reserve the right to charge handling fee if returned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is...

Page 23: ...C SELECT 6 Emergency power off connector port D OFF ENTER 7 USB RS232 ports 1 Standard UPS outlets 8 Intelligent SNMP port 2 Programmable outlets 9 External Battery connector optional in some models 3...

Page 24: ...INDEX USER MANUAL OPTIMA RT10 1K 1 5K 2K 3K UL www xmart ups com VER 2010 22 One ENG 24...

Page 25: ...5 Electronic inverter shortcircuit protection Protecci n contra cortocircuitos en la salida Triggered by output current over 400 of nominal current during 5 cycles Activaci n a 400 de la corriente no...

Page 26: ...alida es configurable entre 4 alternativas seleccionables en el LCD N2 Backup time for programable outlets can be configurable in minutes Las salidas programables pueden configurarse en minutos N3 All...

Page 27: ......

Page 28: ...USA Headquarters 10540 NW 26th St Doral FL 33172 USA EUROPE Headquarters Ave Can Bordoll 60 Nave 4 Sabadell 08202 Spain Latin America Headquarters Santiago de Chile 8330669 Chile CHILE...

Reviews: