Model No:
Drawing No:
5. TRANSMITTER FREQUENCY ALIGNMENT
Equipment Setting:
Filter : 50Hz~15kHz
IF Filter : PMR 15kHz; LPD : 230kHz
De-Emphasis : OFF
Monitor : Pk-Pk/2
Input : 200mVrms; 1kHz Deviation
5.1 Set the unit/equipment for TX Test
(SEE FIGURE 2).
Set the unit at PMR Ch1. Press the PTT button so
the unit will be in transmit mode.
5.2 Adjust CT201 trimmer capacitor until such that the output frequency is equal to the channel frequency
with maximum error of +/-200Hz
(OQA Limit of +/-800Hz).
Production will control as follows:
- PCBA Alignment : +/-200Hz
- Casing Test : +/-500Hz
- OQA Limit : +/-800Hz
6. TRANSMITTER OUTPUT POWER CHECK
MT2020D
6.1 Set the unit at PMR Ch1. (use short cable)
6.2 Press the PTT button so the unit is in transmit mode.
6.3 Transmit Power should be between
0.4~1.0W.
6.4 Set the unit at LPD Ch1.
6.5 Press the PTT button so the unit is in transmit mode. Ensure the TX Power is
10~70mW.
MT4040D
6.6 Set the Power Supply to 5Vdc. Set the unit at PMR Ch1. (use short cable)
6.7 Press the PTT button so the unit is in transmit mode. Make sure Power Supply is 5Vdc during PTT.
6.8 Transmit Power should be between
1.4~2.5W.
6.9
Solder J3
. Press the PTT button so the unit is in transmit mode. Transmit Power should be between
0.4~1.0W.
6.10 Set the unit at LPD Ch1.
6.11 Press the PTT button so the unit is in transmit mode. Ensure the TX Power is
8~70mW
7. TRANSMITTER DEVIATION ADJUSTMENT
7.1 Set the unit at PMR Ch1. Connect an audio generator (600ohms) to the microphone terminal pads. The
audio frequency should be set at 1kHz with a level of 200mVrms.
7.2 Connect an FM Deviation Meter (on the HP8920B) on ANT point. Set the monitor to read
(Pk to Pk)/2
deviation. Set
Filter 1
to 50Hz and
Filter 2
to 15kHz.
De-emphasis
should be set to Off.
7.3 Press the PTT button so the unit will be in transmit mode.
7.4 Adjust RV2 and observe the reading at the Deviation Meter, the reading should be between
1.5
to
1.8kHz (MT2020D)
/
between
1.8
to
2.1kHz (MT4040D)
.
7.5 Set the unit to LPD Ch1. Set the monitor to read
(Pk to Pk)/2
deviation. Set
Filter 1
to 50Hz and
Filter 2
to 15kHz.
De-emphasis
should be set to Off. Set the
IF Filter
to
230kHz
. Press the PTT button and
check the Deviation Meter, the reading should be
2.8 ~ 5.0kHz.
7.6 At PMR Ch1, decrease the audio generator level until the deviation reads +/-
1.2
kHz. The generator level
should be between
3~10mV
.
7.7 Check that the transmit audio distortion is less than 5%. TX Distortion should be checked at
1.2kHz
Modulation, using Narrowband Filter with De-Emphasis ON.
7.8 Set the CTCSS to Code 1. Turn OFF the audio generator. Press the PTT button so the unit will be in
transmit mode.
7.9 Confirm that the CTCSS Code modulation is between 0.4 to 0.7kHz
7.10 Set the CTCSS to Code 38. Press the PTT button so the unit will be in transmit mode.
7.11 Confirm that the CTCSS Code modulation is between 0.4 to 0.7kHz.
Created by:
Approved by:
Rev. No:
For Stage :
Release Date :
Page 14 of 49
Summary of Contents for MT-4040
Page 4: ...Model No For Stage Release Date Page 4 of 49 r BLOCK DIAGRAM Created by Approved by Rev No ...
Page 5: ...MT 2020D SCHEMATIC DIAGRAM PAGE 5 OF 49 ...
Page 6: ...MT 4040D SCHEMATIC DIAGRAM PAGE 6 OF 49 ...
Page 9: ...MT 2020D TOP PCB MAP PAGE 9 OF 49 ...
Page 10: ...MT 2020D BOTTOM PCB MAP PAGE 10 OF 49 ...
Page 11: ...MT 4040D TOP PCB MAP PAGE 11 OF 49 ...