Configuring BIOS for Intel RAID for Serial ATA on Intel Motherboards
R
11.2
Create RAID 0 or RAID 1 Volume
Note:
Please refer to Section 13 for illustration examples of the Intel Application Accelerator RAID
option ROM windows.
1. Select option
1 Create RAID Volume
and press the
<Enter>
key.
2. If you selected RAID 0, select the RAID level and press the <Enter> key.
3. Select the strip value for the RAID array by scrolling through the available values by using
the <
Ç
> or <
È
> keys and pressing the <Enter> key.
4. The available values range from 4 KB to 128 KB in power of 2 increments. The strip value
should be chosen based on the planned drive usage. Some suggested selections are listed
below. The default selection is 128 KB.
16 KB – low disk usage
x
x
x
64 KB – typical disk usage
128 KB – performance disk usage
5. At the Create Volume prompt, press the <Enter> key to create the array. Confirm this
selection by pressing the <Y> key after the prompt.
6. Scroll to option 4 Exit and press the <Enter> key to exit the RAID Configuration utility.
Confirm the exit by pressing the <Y> key.
11.3
Delete RAID Volume
Note:
Please refer to Section 13 for illustration examples of the Intel Application Accelerator RAID
option ROM windows.
Warning:
All data on the RAID drives will be lost.
1. Select option 2 Delete RAID Volume and press the <Enter> key to delete the RAID volume.
2. Use the up and down arrow keys to select the volume you would like to delete.
3. Press the <Delete> key to delete the RAID volume. Confirm the volume deletion by pressing
the <Y> key.
11.4
Reset RAID Data
Note:
Please refer to Section 13 for illustration examples of the Intel Application Accelerator RAID
option ROM windows.
Warning:
All data on the RAID drives and any internal RAID structures will be lost.
1. Select option 3 Reset Disks to Non-RAID and press the <Enter> key to delete the RAID set
and remove any RAID structures from the drives.
32
User's Manual
Summary of Contents for Application Accelerator
Page 1: ...Intel Application Accelerator User s Manual Revision 2 0 June 2004 ...
Page 8: ...R This page is intentionally left blank 8 User s Manual ...
Page 10: ...Scope of This Document R This page is intentionally left blank 10 User s Manual ...
Page 12: ...RAID Background R This page is intentionally left blank 12 User s Manual ...
Page 14: ...RAID 0 Striping R This page is intentionally left blank 14 User s Manual ...
Page 16: ...RAID 1 Mirroring R This page is intentionally left blank 16 User s Manual ...
Page 18: ...Matrix RAID Two Volumes Per Array R This page is intentionally left blank 18 User s Manual ...
Page 20: ...RAID Migration Feature R This page is intentionally left blank 20 User s Manual ...
Page 23: ...Advanced Host Controller Interface Native Command Queuing R User s Manual 23 ...
Page 26: ...Intel Application Accelerator R This page is intentionally left blank 26 User s Manual ...
Page 30: ...BIOS Importance Settings R This page is intentionally left blank 30 User s Manual ...
Page 57: ...Issues During Installation R This page is intentionally left blank User s Manual 57 ...