28
C H A P T E R
2
Intel Express 100BASE-TX Switching Hub
sys-stat
Displays general status information about the switch and its SNMP
agent hardware and software:
SYS_console>sys-stat
Intel Express Switching Hub
SNMP Agent Software - Version V2.2 Nov 7 1995 15:01:09
SNMP Object ID is : < .1.3.6.1.4.1.629.1.1.3 >
System MAC Address : 00-A0-C9-00-20-D9
Total uptime(hundredths of seconds ): 111151888
Total uptime(days, hh:mm:ss format): 12 days, 20:45:18.88
i/f 1 -- description [ Port 1 - missing ] —- status [DOWN]
i/f 2 -- description [ Port 2 - missing ] —- status [DOWN]
i/f 3 -- description [ Port 3 - 100 BaseTX Ethernet Port] -- status [up]
i/f 4 -- description [ Port 4 - 100 BaseTX Ethernet Port] -- status [up]
i/f 5 -- description [ Port 5 - 100 BaseTX Ethernet Port] -- status [up]
i/f 6 -- description [ Port 6 - 100 BaseTX Ethernet Port] -- status [up]
i/f 7 -- description [ Port 7 - 100 BaseTX Ethernet Port] -- status [up]
The screen displays the following information:
•
SNMP agent software version and release date.
•
Device SNMP object ID
•
Device MAC address.
•
System uptime (in 1/100 of a second) and in days, hours, minutes,
and seconds.
•
Port description and status. Ports 1 and 2 appear as missing unless
you have optional media adapters installed.
warm-reset
Resets the SNMP agent software without resetting the switch (it
doesn’t disconnect existing connections). The switch configuration is
loaded from the values saved in NVRAM. The statistics counters are
also reset by this command.
cold-reset
Performs a cold reset, which is equivalent to turning the power off
and on again. Existing connections are also lost.
Summary of Contents for Express 100BASE-TX
Page 1: ...Intel Express 100BASE TX Switching Hub User Guide Part No 654655 001 ...
Page 18: ......
Page 62: ......
Page 76: ......