18
Removing and Installing the Redundant Power
Supply Unit
The server chassis is equipped with two redundant power supply units. Each of
them can be hot-swappable.
Caution:
Installing two power supply units with different wattage ratings in a server
chassis is not supported. Doing so will not provide power supply redundancy and
will result in multiple errors being logged.
Removing the Power Supply Unit
While pressing the latch, pull out the handle with the power supply unit.
Figure 25. Removing the Power Supply Unit
Installing the Power Supply Unit
1. Align and slide the power supply unit into the power cage.
2. While pressing the latch, push the power supply unit along the power cage
rail until the latch locks in position.
Figure 26. Installing the Power Supply Unit
Handle
Latch
AF006675
Handle
Latch
AF006674