28
Intel
®
Modular Server System Service Guide
2. Press the retention lever latch button to release the retention lever (see letter “A” in
Figure 15
).
3. Rotate the lever out and away from the module bay (see letter “B” in
Figure 15
) and
pull the storage control module straight out the back of the chassis (see letter “C” in
Figure 15
).
Warning:
You must replace the storage control module with a filler panel or
another storage control module within two minutes.
Figure 15. Removing a Storage Control Module
4. Install a filler panel or another storage control module in the storage control module
bay within two minutes.
AF002430
A
C
B