Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
3
1.2
Server Building Block Installation
1.2.1
Removing the Chassis Side Cover
Loosen the two screws located on the back edge of the chassis side cover (see letter “A”).
Slide the cover and lift it away (see letter “B”).
Take out the material from the chassis inside.
1.2.2
Installing the IO Shield
Note:
The IO shield can be found in the retail board package, or can be ordered separately.
From the chassis inner side, align the IO shield to the chassis rear IO opening.
Press the IO shield firmly to the chassis rear IO opening until it clicks into place. To make the process
easier, install one end of the IO shield first and finish by pressing the other end.
1.2.3
Installing the Chassis Stand-off
Install the stand-off to the chassis mounting holes aligning to the positions on the server board.