Appendix B: Integrated BMC Sensor Tables
Intel®
Server Board S1200V3RP TPS
Revision 1.2
222
Full Sensor
Name
(Sensor name
in SDR)
Se
ns
or
#
Platform
Applicabilit
y
Sensor
Type
Event/R
eading
Type
Event Offset Triggers
Contrib.
To
System
Status
Assert
/De-
assert
Reada
ble
Value/
Offset
s
Event
Data
Rearm St
an
db
y
(IPMI
Watchdog)
23h
c
6Fh
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical
Security
(Physical
Scrty)
04
h
Chassis
Intrusion
is
chassis-
specific
Physica
l
Securit
y
05h
Sensor
Specifi
c
6Fh
00 - Chassis intrusion
Degrad
ed
OK
As
and
De
–
Trig
Offset
A
X
04 - LAN leash lost
FP Interrupt
(FP NMI
Diag Int)
05
h
Chassis -
specific
Critical
Interrup
t
13h
Sensor
Specifi
c
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK
As
–
Trig
Offset
A
–
SMI Timeout
(SMI
Timeout)
06
h
All
SMI
Timeou
t
F3h
Digital
Discret
e
03h
01
– State asserted
Fatal
As
and
De
–
Trig
Offset
A
–
System
Event Log
(System
Event Log)
07
h
All
Event
Loggin
g
Disable
d
10h
Sensor
Specifi
c
6Fh
02 - Log area
reset/cleared
OK
As
–
Trig
Offset
A
X
System
Event
(System
Event)
08
h
All
System
Event
12h
Sensor
Specifi
c
6Fh
02 - Undetermined
system H/W failure
Fatal
As
and
De
As
-
Trig
Offset
A
X
04
– PEF action
OK
Button
Sensor
(Button)
09
h
All
Button/
Switch
14h
Sensor
Specifi
c
6Fh
00
– Power Button
OK
AS
_
Trig
Offset
A
X
02
– Reset Button
BMC
Watchdog
0
A
h
All
Mgmt
System
Health
28h
Digital
Discret
e
03h
01
– State Asserted
Degrad
ed
As
–
Trig
Offset
A
-
Voltage
Regulator
Watchdog
(VR
Watchdog)
0
B
h
All
Voltage
02h
Digital
Discret
e
03h
01
– State Asserted
Fatal
As
and
De
–
Trig
Offset
M
X
Fan
Redundancy
1
(Fan
Redundancy
)
0
C
h
Chassis-
specific
Fan
04h
Generi
c
0Bh
00 - Fully redundant
OK
As
and
De
–
Trig
Offset
A
–
01 - Redundancy lost
Degrad
ed
02 - Redundancy
degraded
Degrad
ed
03 - Non-redundant:
Degrad
Summary of Contents for S1200V3RP