Platform Management Functional Overview
Intel®
Server Board S1200V3RP TPS
Revision 1.2
42
6.
Platform Management Functional Overview
Platform management functionality is supported by several hardware and software components
integrated on the server board that work together to control system functions, monitor and report
system health, and control various thermal and performance features in order to maintain (when
possible) server functionality in the event of component failure and/or environmentally stressed
conditions.
This chapter provides a high level overview of the platform management features and
functionality implemented on the server board. For more in depth and design level Platform
Management information, refer to the
BMC Core Firmware External Product Specification (EPS)
and
BIOS Core External Product Specification (EPS)
for Intel
®
Server products based on the
Intel
®
Xeon
®
processor E3-1200 V3 product families.
6.1
Baseboard Management Controller (BMC) Firmware Feature Support
The following sections outline features that the integrated BMC firmware can support. Support
or utilization for some features is dependent on the server platform in which the server board is
integrated and any additional system level components and options that may be installed.
6.1.1
IPMI 2.0 Features
Baseboard management controller (BMC)
IPMI Watchdog timer
Messaging support, including command bridging and user/session support
Chassis device functionality, including power/reset control and BIOS boot flags support
Event receiver device: The BMC receives and processes events from other platform
subsystems.
Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access
to system FRU devices using IPMI FRU commands.
System Event Log (SEL) device functionality: The BMC supports and provides access to
a SEL.
Sensor Data Record (SDR) repository device functionality: The BMC supports storage
and access of system SDRs.
Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of
sensors. It polls sensors to monitor and report system health.
IPMI interfaces
-
Host interfaces including system management software (SMS) with receive message
queue support, and server management mode (SMM)
-
IPMB interface
-
LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+)
Serial-over-LAN (SOL)
ACPI state synchronization: The BMC tracks ACPI state changes that are provided by
the BIOS.
BMC self test: The BMC performs initialization and run-time self-tests and makes results
available to external entities.
Summary of Contents for S1200V3RP
Page 14: ......