Appendix C: Integrated BMC Sensor Tables
Intel® Server Board S2600CO Family TPS
Revision 1.4
Intel order number G42278-004
124
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/
Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
(Fan Redundancy)
specific
04h
0Bh
01 - Redundancy lost
Degraded
and
De
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 – Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperature
01h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
– Trig
Offset
M X
IO Module Presence
(
IO Mod Presence
)
0Eh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
– Trig
Offset
M X
SAS Module Presence
(
SAS Mod Presence
)
0Fh
Platform-
specific
Module/Boar
d
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
– Trig
Offset
M X
BMC Firmware Health
(
BMC FW Health
)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor Failure
Degraded
As - Trig
Offset
A X
System Airflow
(
System Airflow
)
11h All
Other Units
0Bh
Threshold
01h
– –
–