54
Intel® Server Chassis SC5400 User’s Guide
Replacing the Power Distribution Board
Warning:
Hazardous voltage, current, and energy levels are present inside the power supply. There
are no user-serviceable parts inside it; servicing should be done by technically qualified
personnel.
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see
“Removing the Chassis Cover” on
page 16
.
4. Remove the memory and processor air ducts. For instructions, see
“Removing the
Processor and Memory Air Ducts” on page 20
.
5. If present, remove shipping screw securing hot swap power supply to chassis (see
letter “A” in the following figure). Press on green latch (see letter “B”) while
pulling on handle to remove power supply from chassis. Repeat this step for the
second hot swap power supply if one is installed.
Figure 58. Removing Hot Swap Power Supply from Chassis
6. Disconnect all internal power cables from chassis components and server board.
AF000956
A
B
Summary of Contents for SC5400
Page 6: ...vi Intel Server Chassis SC5400 User s Guide...
Page 10: ...x Intel Server Chassis SC5400 User s Guide...
Page 18: ...xviii Intel Server Chassis SC5400 User s Guide...
Page 32: ...14 Intel Server Chassis SC5400 User s Guide...
Page 80: ...62 Intel Server Chassis SC5400 User s Guide...
Page 108: ...128 Intel Server Chassis SC5400 User s Guide...
Page 133: ...Intel Server Chassis SC5400 User s Guide 111 Intel Intel Intel Web...
Page 134: ...112 Intel Server Chassis SC5400 User s Guide ITE ITE 5V...
Page 135: ...Intel Server Chassis SC5400 User s Guide 113...
Page 136: ...114 Intel Server Chassis SC5400 User s Guide ESD ESD ESD ESD ESD...
Page 137: ...Intel Server Chassis SC5400 User s Guide 115...
Page 138: ...116 Intel Server Chassis SC5400 User s Guide...