Connector Definitions and Pin-outs
Intel® Server Boards SE7320SP2 and SE7525GP2
Revision
4.0
160
7.16.2
Rolling BIOS Bank Selection Jumper
An additional 3-pin jumper header (J26) is provided to support the Rolling BIOS functionality.
This jumper is located near the processor 2 VRD heatsink and the SATA connectors on the
board. The jumper provides the option to force the board to boot from Bank 0 as part of the
Rolling BIOS feature. The figure below shows the factory default location for the jumper option.
Figure 20. BIOS Bank Jumper (J26)
The following table describes the jumper option.
Table 98. BIOS Bank Jumper Option
Option
Description
Auto
If pins 1 and 2 are jumpered (default), the platform instrumentation on the board controls which BIOS
bank has the BIOS the board is intended to boot from.
Force
Bank0
If pins 2 and 3 are jumpered, the server board is forced to boot by using the BIOS code stored in
Bank0.
Summary of Contents for SE7320SP2 - 800MHZ Ecc Ddr Xeon