Server Utilities
Upgrading the BIOS
Follow the instructions in the readme file that came with the BIOS upgrade. When the update
completes, remove the bootable media from which you performed the upgrade.
✏
NOTES
Do not power down the system during the BIOS update process! The system
will reset automatically when the BIOS update process is completed.
You may encounter a CMOS Checksum error or other problem after reboot. If this
happens, shut down the system and boot it again. CMOS checksum errors require
that you enter Setup, check your settings, save your settings, and exit Setup.
Clearing the Password
If the user or administrator password(s) is lost or forgotten, moving the password clear jumper into
the “clear” position clears both passwords. The password clear jumper must be restored to its
original position before a new password(s) can be set. The password clear jumper is located on
jumper block J1H2.
1.
Power down the system and disconnect the AC power.
2.
Open the server chassis.
3.
Move the jumper from the normal operation position, Password Clear Protect, at pins 2 and 3 to
the Password Clear Erase position, covering pins 1 and 2 as indicated in the following diagram.
Figure 14. Password Recovery Jumper
37
Summary of Contents for SE7320VP2
Page 1: ...Intel Server Board SE7320VP2 User Guide Order Number C71354 002 ...
Page 10: ...Preface x ...
Page 14: ...Contents xiv ...