Intel
®
Server Board SE7500WV2 Training
Student Workbook
42
© 2003 Intel Corporation
Jumpers and Additional Headers
© 2003 Intel Corporation.
*Other names and brands may be claimed as the property of others.
Intel
®
Server Board SE7500WV2
Jumpers and Additional Headers
•
System recovery and
update jumpers
–
Recovery boot
–
Password clear
–
CMOS clear
–
BMC boot block write
enable
•
Headers
–
Chassis intrusion header
–
HDD activity header
The SE7500WV2 includes two rows of jumper pins that perform a variety of functions:
•
Recovery boot jumper:
Forces the server board to boot into BIOS recovery mode in the case of a corrupt BIOS.
When the pins are open (default) the system boots using the existing BIOS. When the pins are closed with a jumper,
the system attempts a recovery boot and loads the BIOS code from a floppy disk.
•
Password clear jumper:
Clears all passwords set in BIOS. When the pins are open (default) the current BIOS
passwords are maintained. When the pins are closed with a jumper, the password is cleared upon system reset.
•
CMOS clear jumper:
Resets all BIOS settings to default, with the exception of BIOS passwords. When the pins are
open (default) CMOS configuration is preserved. When the pins are closed with a jumper, the CMOS configuration
returns to factory default upon reset.
•
BMC boot block write enable jumper:
By default, the BMC boot block code is write-protected. This jumper is
used to write-enable the BMC boot block code when updates are necessary.
•
Chassis intrusion header:
This header is used when the SE7500WV2 is integrated into a third-party chassis. When
the chassis intrusion header pins are cabled to the chassis, a switch installed on the chassis indicates that the cover
has been removed. Closing the chassis intrusion header pins with a jumper disables the chassis intrusion feature.
•
Hard drive activity header:
This header is used in conjunction with add-in drive controller cards and RAID cards,
and provides a pass-through connection to the hard drive activity LED on the front panel.
Note
: When the SE7500WV2 is installed in either the SR1300 chassis or the SR2300 chassis, chassis intrusion detection
is integrated into the front panel.
Summary of Contents for SE7500WV2 - Server Chassis - SR2300
Page 1: ...Intel Server Board SE7500WV2 Training Student Workbook...
Page 6: ...Intel Server Board SE7500WV2 Training Student Workbook vi 2003 Intel Corporation...
Page 8: ...Intel Server Board SE7500WV2 Training Student Workbook 2 2003 Intel Corporation...
Page 10: ...Intel Server Board SE7500WV2 Training Student Workbook 4 2003 Intel Corporation...
Page 52: ...Intel Server Board SE7500WV2 Training Student Workbook 46 2003 Intel Corporation...
Page 110: ...Intel Server Board SE7500WV2 Training Student Workbook 104 2003 Intel Corporation...
Page 114: ...Intel Server Board SE7500WV2 Training Student Workbook 108 2003 Intel Corporation...
Page 115: ......