64
Intel Server Board SE7501CW2 Product Guide
1. Re-insert the heat sink over the top of the processor. Make sure to face the flat edge of the heat
sink towards the rear of the chassis.
2. Reconnect the retention mechanism clips. See Figure 15.
3. Reattach the fan assembly to the retention mechanism. Pull the tabs at the sides of the retention
mechanism apart slightly. See Figure 18, 1a. Lower the fan assembly into the retention
mechanism. The tabs on the fan assembly (Figure 18, 2a) will fit into the slots of the retention
mechanism (Figure 18, 2b). Pull out on the tabs located at the bottom of the fan assembly to
snap them into place on the retention mechanism (Figure 18, 3a and 3b).
4. Reattach the CPU fan
Replacing the Backup Battery
The lithium battery on the server board powers the RTC for up to 10 years in the absence of power.
When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in
the RTC (for example, the date and time) may be wrong. Contact your customer service
representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with
the same or equivalent type recommended by the equipment
manufacturer. Discard used batteries according to manufacturer’s
instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri
som anbefalt av apparatfabrikanten. Brukt batteri returneres
apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller
en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera
använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty
paristo valmistajan ohjeiden mukaisesti.