Intel® Server Board SE7501WV2
Installation Guidelines
Revision 3.5
43
6. Installation
Guidelines
6.1 Novell NetWare* 6.0 fails to detect the Promise Fast Track
TX2000 adapter when the on-board Promises driver is enabled
Issue:
Novell NetWare 6.0 fails to detect the Promise Fast Track TX2000 adapter with
the on-board Promise driver enabled.
Implication:
While attempting to bind the driver with the adapter, an error message appears:
“The following driver instance failed to load and will be deleted:
c:\NWUPDATE\FASTTRACK.HAM SLOT=1
(The device supported by the driver may be disabled)”
The Logger screen shows:
“Module FASTTRACK.HAM load status REENT FAIL”
Guideline:
Disable the on-board Promise driver.
Status:
Intel is currently working to determine root cause of this issue.
6.2 SuSE* 8.0 installation hangs while formatting a hard drive on
Adaptec ASC39320
Issue:
SuSE installation hangs while formatting a hard drive on the Adaptec ASC39320
Implication:
The hard drive will not be formatted and the installation of the SuSE 8.0
operating system will not be complete.
Guideline:
Use the on-board Adaptec component when formatting hard drives during
installation.
Status:
Intel is currently working to determine root cause of this issue.
6.3 SuSE* 8.0 installation must be completed before the installing
Adaptec ASR-2110
Issue:
SuSE installation will panic if ASR2110 is installed before the completion of the
OS
Implication:
The hard drive will not be formatted and the installation of the SuSE 8.0