Platform Management
Intel® Server Board SE7520AF2 TPS
180
Revision
1.2
Intel order number C77866-003
Sensor Name
Se
ns
or #
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value/Offsets
Event Data
PEF
Action
SDR
Record
Type
CPU 2 Thermal
Throttle
23h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Diagnostic Interrupt
Button
24h
Critical
Interrupt
13h
Sensor
Specific
6Fh
FP NMI Button
As
–
Trig Offset NMI Pulse
02
Chassis Identify
Button
25h
Button
14h
Generic
03h
Sate
Deasserted
State Assert
As & De
–
Trig Offset
ID LED
Action
02
Proc1 Fan
26h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc2 Fan
27h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc1 Core temp
28h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
R, T
Fault LED
Action
01
Proc2 Core temp
29h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
R, T
Fault LED
Action
01
CPU Configuration
Error
2Ah
Processor
07h
Generic
03h
State Asserted
As & De
Discrete
R, T
Fault LED
Action
02
Baseboard Temp 1 2Bh
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
Trig Offset
Fault LED
Action
01
Baseboard Temp 2 2Ch
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
Trig Offset
Fault LED
Action
01
Front Panel Temp
2Dh
Temp
01h
Threshold
01h
[u,l][ nr, c,nc]
As & De
Analog
Trig Offset
Fault LED
Action
01
The following table shows the platform sensors that are supported by the Intel® Management
Module (IMM) Professional and Advanced Editions when installed on the Intel® Server Board
SE7520AF2 and updated with SE7520AF2 platform specific firmware.
Table 81. Platform Sensors for the Intel® Management Module
Sensor Name
Se
ns
or #
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value /
Offsets
EventData
Rearm
Sta
ndby
Power Unit Status
01h
Power Unit
09h
Sensor
Specific
6Fh
Power Off
Power Cycle
A/C Lost
Soft Power
Control Fault
Power Unit Failure
Predictive Failure
As –
Trig
Offset
A
X