Appendix C: POST Error Beep Codes
Intel® Server System SR2500AL
Revision – 1.6
Intel order number D31980-009
96
Appendix C: POST Error Beep Codes
The following table lists POST error beep codes. Prior to system Video initialization, BIOS uses
these beep codes to inform users on error conditions. The beep code is followed by a user
visible code on POST Progress LEDs.
Table 58. POST Error Beep Codes
Beeps
Error Message
POST Progress Code
Description
3
Memory error
System halted because a fatal error related to the memory
was detected.
6
BIOS rolling back
error
The system has detected a corrupted BIOS in the flash
part, and is rolling back to the last good BIOS.
The BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered, such as on each power-up attempt, but are not
sounded continuously. Codes that are common across all Intel
®
server boards and systems that
use the Intel
®
5000 Series Chipsets are listed in Table 59. Each digit in the code is represented
by a sequence of beeps whose count is equal to the digit.
Table 59. BMC Beep Codes
Code
Reason for Beep
Associated Sensors
Supported?
1-5-2-1
CPU: Empty slot / population error – Processor
slot 1 is not populated.
CPU Population Error
Yes
1-5-2-2
CPU: No processors (terminators only)
N/A
No
1-5-2-3
CPU: Configuration error (e.g., VID mismatch)
N/A
No
1-5-2-4
CPU: Configuration error (e.g., BSEL mismatch) N/A
No
1-5-4-2
Power fault: DC power unexpectedly lost (power
good dropout)
Power Unit – power unit
failure offset
Yes
1-5-4-3
Chipset control failure
N/A
No
1-5-4-4
Power control fault
Power Unit – soft power
control failure offset
Yes
Summary of Contents for SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory