background image

Intel® Server System SR2500AL

 

10BEnvironmental and  Regulatory Specifications 

Revision – 1.6 

 

 

Intel order number D31980-009 

83

Table 55. Product Safety & Electromagnetic (EMC) Compliance 

Compliance Regional 

Description 

Compliance 

 

Reference 

Compliance Reference Marking Example

Australia / New Zealand  AS/NZS 3548 (Emissions) 

 

N232

 

 Argentina  

IRAM Certification (Safety) 

 

 Belarus 

 

Belarus Certification

 

None Required 

CSA 60950 – UL 60950 
(Safety) 

 

Industry Canada ICES-003 
(Emissions) 

CANADA ICES-003 CLASS A 

CANADA NMB-003 CLASSE A 

 Canada / USA  

FCC  
CFR 47, Part 15 (Emissions) 

This device complies with Part 15 of the 

FCC Rules. Operation of this device is 
subject to the following two conditions: 
(1) This device may not cause harmful 

interference, and (2) This device must 

accept interference receive, including 

interference that may cause undesired operation.

 

 China

 

CNCA – CB4943 (Safety)

 

GB 9254 (Emissions) 
GB17625 (Harmonics)

 

 

 CENELEC Europe

 

Low Voltage Directive 

93/68/EEC

;

EMC Directive 

89/336/EEC

 

EN55022 (Emissions) 
EN55024 (Immunity)  
EN61000-3-2 (Harmonics) 
EN61000-3-3 (Voltage Flicker) 
CE Declaration of Conformity 

 

 

Germany 

GS Certification – EN60950

 

 

 International 

CB Certification – IEC60950 
CISPR 22 / CISPR 24

 

None Required 

 Japan 

VCCI Certification 

 

 Korea 

RRL Certification  
MIC Notice No. 1997-41 (EMC) 
& 1997-42  (EMI) 

 

인증번호

: CPU-Model Name

 

(A)

 

Russia

 

GOST-R Certification 
GOST R 29216-91 (Emissions) 
GOST R 50628-95 (Immunity)

  

 

Summary of Contents for SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory

Page 1: ...Intel Server Chassis SR2500 Intel Server System SR2500AL Technical Product Specification Intel order number D31980 009 Revision 1 6 November 2008 Enterprise Platforms and Services Division Marketing...

Page 2: ...pdated fan numbering orientation January 2007 1 2 Updated ASR2500FHR population table Updated figure 16 Updated regulatory section February 2007 1 3 Updated power supply illustrations to show proper p...

Page 3: ...d shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them The Intel Server System SR2500AL may contain design defects or errors known as errata w...

Page 4: ...er Supply Module Population 12 2 3 Handle and Retention Mechanism 12 2 4 Hot swap Support 12 2 5 Airflow 13 2 6 AC Power Cord Specification Requirements 13 2 7 Output Cable Harness 13 2 7 1 P1 Server...

Page 5: ...28 5 2 Bridge Board 36 5 3 Hot Swap SATA SAS Backplane 36 6 Peripheral and Hard Drive Sub System 44 6 1 Slimline Drive Bay 44 6 2 Hard Drive Bays 46 6 2 1 Hot swap Drive Trays 46 6 3 Optional Tape Dr...

Page 6: ...or Support 79 11 Environmental and Regulatory Specifications 80 11 1 System Level Environmental Limits 80 11 2 Serviceability and Availability 80 11 3 Replacing the Back up Battery 81 11 4 Product Reg...

Page 7: ...ure 14 Power Supply Blank 12 Figure 15 Non Redundant Fan Module 21 Figure 16 Non Redundant Fan Header Assignments on Mid plane 22 Figure 17 Fan Module Assembly 23 Figure 18 Redudant Fan Header Assignm...

Page 8: ...igure 40 Control Panel LEDs 58 Figure 41 Standard Control Panel PCB 63 Figure 42 Intel Local Control Panel Assembly Module 65 Figure 43 Intel Local Control Panel Overview 65 Figure 44 Low Profile PCIe...

Page 9: ...eader Assignment 25 Table 19 120 pin Server Board to Mid plane Bridge Board Connector Pin out 29 Table 20 Mid plane Fan Header Pin outs 31 Table 21 Mid plane Power Connector Pin out 31 Table 22 Mid pl...

Page 10: ...Table 43 Control Panel LED Functions 59 Table 44 SSI Power LED Operation 60 Table 45 Control Panel LED Operation 60 Table 46 External USB Connectors J1B1 62 Table 47 Video Connector J1A1 62 Table 48...

Page 11: ...Intel Server System SR2500AL List of Tables Revision 1 6 Intel order number D31980 009 xi This page intentionally left blank...

Page 12: ......

Page 13: ...the system and in their place are a series of board to board interconnects The benefits of using board to board interconnects are simplification of platform integration and improved airflow for more r...

Page 14: ...5 Depth with CMA 838 2 mm 33 0 Max Weight 29 5 kg 65 lbs 1 3 System Components TP02094 A B D C E F G H I A L K J M N Figure 4 Major Chassis Components A Rack Handles H CPU Air Duct B SAS SATA Backplan...

Page 15: ...s The complete system includes the use of several system boards which are used as internal interconnects and provide feature accessibility The following provides a brief description for each Bridge Bo...

Page 16: ...re available for this system o Hardware RAID Activation Key Used on the Active SAS SAS RAID Mid plane to enable hardware RAID support o Software SATA RAID 5 Activation Key This RAID key plugs into a c...

Page 17: ...essibility The following diagram overviews the layout and functions of the control panel TP02098 L J K H I B A F G E D C Figure 7 Standard Control Panel Overview A NIC 2 Activity LED G System Identifi...

Page 18: ...agram provides an overview of this control panel TP02099 O M L K J H I N G C D E F B A Figure 8 LCD Control Panel Overview A USB 2 0 Port I Power Sleep Button B LCD Display J System Status LED C Menu...

Page 19: ...System Control Panel D 3 5 Hard Drive Bays 5 1 7 Power Sub system The power subsystem of the chassis consists of an integrated power distribution board and module enclosure which is capable of housing...

Page 20: ...5 1 fan configuration Refer to section 3 2 for details Should a single fan failure occur this option provides support for hot swap fans and fan redundancy In addition to the system fan options each p...

Page 21: ...ront Bezel Separate front bezels are available to support systems that use either a standard control panel or the Intel Local Control Panel with LCD support When the standard control panel is used lig...

Page 22: ...er number D31980 009 10 When the local control panel is used the control panel module can be adjusted to extend further out from the chassis face to allow the LCD panel to protrude from the front beze...

Page 23: ...failed power module can be hot swapped with the system running Either configuration will support up to a maximum of 750 Watts of power This chapter provides technical details to the operation of the...

Page 24: ...inserted This mechanism will withstand the specified platform mechanical shock and vibration requirements The tab on the retention mechanism is colored green to indicate it is a hot swap touch point...

Page 25: ...lowing specification requirements Cable Type SJT Wire Size 16 AWG Temperature Rating 105 C Amperage Rating 13A Voltage Rating 125V 2 7 Output Cable Harness The power distribution board provides a cabl...

Page 26: ...OM Black 4 5 VDC Red 16 PS_ON Green 5V RS Red 24 AWG 17 COM Black 5 COM Black 18 COM Black 6 5 VDC Red 19 COM Black 7 COM Black 20 Reserved 5V in ATX N C 8 PWR OK Gray 21 5 VDC Red 9 5Vsb Purple 22 5...

Page 27: ...nnector PIN SIGNAL 18 AWG COLORS PIN SIGNAL 18 AWG COLORS 1 COM Black 5 12 V4 Yellow Green 2 COM Black 6 12 V4 Yellow Green 3 5V Red 7 5Vsb Purple 4 5V Red 8 3 3V Orange 2 7 5 P5 Mid plane Power Conne...

Page 28: ...4 Maximum rated input current is measured at 100VAC and 200VAC Harmonic distortion of up to 10 of the rated AC input voltage must not cause the power supply to go out of specified limits The power su...

Page 29: ...PS and PDB shall shutdown and latch off after an over current condition occurs This latch shall be cleared by an AC power interruption The following table provides the over current limits The values a...

Page 30: ...r Currents The following table defines power and current ratings for this 750W continuous 860W pk power supply in 1 0 or 1 1 redundant configuration The combined output power of both outputs shall not...

Page 31: ...dition Bi Color LED No AC power to all power supplies OFF No AC power to this PSU only for 1 1 configuration or Power supply critical event causing a shutdown failure fuse blown 1 1 only OCP OVP Fan F...

Page 32: ...ble speed fan The chassis uses a variable fan speed control engine to provide adequate cooling for the system at various ambient temperature conditions under various server workloads and with the leas...

Page 33: ...fan Each fan within the module is capable of supporting multiple speeds If the internal ambient temperature of the system exceeds the value programmed into the thermal sensor data record SDR the BMC...

Page 34: ...eserved unused by the non redundant fan 2 PWM Fan speed control signal 3 12V Power for fan 4 12V Power for fan 5 Tachometer A Fan RPM sensor output Two pulse per revolution for the 80mm fan Four pulse...

Page 35: ...t detection signal and a fault LED signal allowing it to be monitored independently by server management software The following table provides the pin out and description for the connectors on each fa...

Page 36: ...ulses per revolution for the 80mm fan Four pulses per revolution for the 60mm fan 6 Return Return path to ground 7 Return Return path to ground 8 Fan Presence Detection if fan is installed in system 9...

Page 37: ...h fan connector within the module supplies a tachometer signal that allows the BMC to monitor the status of each fan If one of the fans should fail the remaining fans will increase their rotation and...

Page 38: ...ough the CPU air duct and out through ventilation holes on both the back wall and rear side wall of the chassis The CPU air duct is used to direct air flow through the processor heat sinks for both si...

Page 39: ...control include Baseboard Management Controller functions of the ESB 2 LM94 Sensor Monitoring Chip Platform Sensors Variable Speed System Fans System BIOS BMC Firmware Sensor Data Records as loaded b...

Page 40: ...design and use along with that of the bridgeboard and hot swap backplane improve cable routing within the system The mid plane is the key system board of the chassis It serves as the primary interfac...

Page 41: ...or B Power Connector H Fan 3 Connector C Mini DIMM Connector I Fan 1 Connector D Fan 6 Connector J Fan 2 Connector E Fan 5 Connector K RAID Activation Key Connector F Bridge Board Connector L Backplan...

Page 42: ...93 USB0_ESB_DP 34 NIC1_LINK_LED_N 94 USB0_ESB_DN 35 NIC1_ACT_LED_N 95 GND 36 LED_STATUS_AMBER_R1 96 FP_NMI_BTN_N 37 NIC2_LINK_LED_N 97 BMC_RST_BTN_N 38 NIC2_ACT_LED_N 98 FP_PWR_BTN_N 39 LED_STATUS_GR...

Page 43: ..._N 8 FAN_PRSNT5_N 9 LED_FAN1_FAULT 9 LED_FAN3_FAULT 9 LED_FAN5_FAULT 10 LED_FAN1 10 LED_FAN3 10 LED_FAN5 J2B2 FAN_2 J3B1 FAN_4 J7B2 FAN_6 PIN SIGNAL NAME PIN SIGNAL NAME PIN SIGNAL NAME 1 FAN_TACH6 1...

Page 44: ...SATA1_TX_N B9 GND A10 GND B10 USB2_ESB_DN A11 GND B11 USB2_ESB_DP A12 USB2_ESB_OC_N B12 GND A13 GND B13 SATA2_RX_N A14 GND B14 SATA2_RX_P A15 SATA3_RX_N B15 GND A16 SATA3_RX_P B16 NC_RESERVEDB16 A17 G...

Page 45: ...SGPIO_LOAD A12 SMB_PBI_3VSB_DAT B12 SMB_IPMB_5VSB_DAT A13 SMB_PBI_3VSB_CLK B13 SMB_IPMB_5VSB_CLK A14 USB0_ESB_OC_N B14 GND A15 GND B15 USB1_ESB_DP A16 GND B16 USB1_ESB_DN A17 USB0_ESB_DP B17 GND A18 U...

Page 46: ...P 2 SATA1_TX_P 3 SATA_ADDIN1_TX_N 3 SATA5_TX_N 3 SATA3_TX_N 3 SATA1_TX_N 4 GND 4 GND 4 GND 4 GND 5 SATA_ADDIN1_RX_N 5 SATA5_RX_N 5 SATA3_RX_N 5 SATA1_RX_N 6 SATA_ADDIN1_RX_P 6 SATA5_RX_P 6 SATA3_RX_P...

Page 47: ...J I K C A Optional RAID Cache Battery Backup Connection G Fan 4 Connector B Power Connector H Fan 3 Connector C Mini DIMM Connector I Fan 1 Connector D Fan 6 Connector J Fan 2 Connector E Fan 5 Connec...

Page 48: ...ontrol signals video various I2C buses fan control signals and a PCIe x4 bus for SAS controller function See Table 19 120 pin Server Board to Mid plane Bridge Board Connector Pin out AF000037 Figure 2...

Page 49: ...de View A Slimline Optical Drive Connector C Control Panel Connector B USB Floppy Connector D SAS SATA Hot Swap Connectors AF000044 A B C D E Figure 26 Hot Swap SAS SATA Backplane Back Side View A Pow...

Page 50: ...ion SATA SAS I O Connector Pin out J4L1 Pin Signal Name 1 Ground 2 SASS_TX_DP 3 SASS_TX_DN 4 Ground 5 SASS_RX_DN 6 SASS_RX_DP 7 Ground Table 29 2x22 Slim Line IDE Optical Drive Connector Pin out J5N1...

Page 51: ...B12 Ground A13 RIDE_DD 15 0 2 B13 RIDE_DD 15 0 14 A14 Ground B14 Ground A15 RIDE_DD 15 0 1 B15 RIDE_DD 15 0 15 A16 Ground B16 Ground A17 RIDE_DD 15 0 0 B17 RIDE_DDREQ A18 Ground B18 Ground A19 RIDE_DI...

Page 52: ...A11 Ground B11 SGPIO_LOAD A12 SMB_PB1_5VSB_DAT B12 SMB_IPMB_5VSB_DAT A13 SMB_PB1_5VSB_CLK B13 SMB_IPMB_5VSB_CLK A14 USB_OC1_N B14 Ground A15 Ground B15 USB_P2P A16 Ground B16 USB_P2N A17 USB_P1P B17 G...

Page 53: ...B_OC3_N B12 Ground A13 Ground B13 SAS2_RX_DN A14 Ground B14 SAS2_RX_DP A15 SAS3_RX_DN B15 Ground A16 SAS3_RX_DP B16 Not Used A17 Ground B17 SMB_SAS_3V3_SDA A18 Ground B18 Not Used A19 Ground B19 SMB_S...

Page 54: ...PMB_5VSB_DAT A15 FP_CHASSIS_INTRU B15 SMB_IPMB_5VSB_CLK A16 Ground B16 Ground A17 SMB_PB1_5VSB_DAT B17 LED_NIC1_ACT_L A18 SMB_PB1_5VSB_CLK B18 LED_NIC1_LINK_R_L A19 Ground B19 FP_PWR_BTN_L A20 FP_NMI_...

Page 55: ...l Description SI Ground S2 SAS _TX_DP 0 4 S3 SAS _TX_DN 0 4 S4 Ground S5 SAS _RX_DN 0 4 S6 SAS _RX_DP 0 4 S7 Ground S8 Not Used S9 Not Used S10 Not Used S11 Not Used S12 Not Used S13 Not Used S14 Not...

Page 56: ...Drive or Tape Drive Bay C System Control Panel D 3 5 Hard Drive Bays x5 Figure 27 Optional 6th Hard Drive Front View 6 1 Slimline Drive Bay The chassis provides a slim line drive bay that is designed...

Page 57: ...nector is the card edge used to connect directly to the hot swap backplane board AF000042 Figure 29 50 pin Connector to Slimline Optical Device Table 39 J1L1 50 pin Connector to Slimline Optical Devic...

Page 58: ...d to support up to 61 hot swap 3 5 x1 SAS or SATA hard disk drives Hard drives are mounted to hot swap drive trays for easy insertion to or extraction from the drive bay 6 2 1 Hot swap Drive Trays Eac...

Page 59: ...the 6th hard drive accessory kit is installed product order code ASR2500SIXDRV This kit includes a backplane board insert power cable and drive carrier To install a 3 5 tape drive both face plates are...

Page 60: ...the hard drive interface support of each of the mid plane boards 6 4 1 Passive Mid plane The passive mid plane is used as an interconnect routing drive control signals from either the on board SATA p...

Page 61: ...F000046 B F A L D C E G H J I K Figure 34 Active Mid plane with SAS SAS RAID Support A RAID Battery Backup Unit Connector G Fan 4 Connector B Power Connector H Fan 3 Connector C Mini DIMM Connector I...

Page 62: ...E G H J I K C A RAID Battery Backup Unit Connector G Fan 4 Connector B Power Connector H Fan 3 Connector C Mini DIMM Connector I Fan 1 Connector D Fan 6 Connector J Fan 2 Connector E Fan 5 Connector...

Page 63: ...integrates the Intel Xscale core with intelligent peripherals and two PCIe to PCI X bridges It will be connected to the server board s x4 PCIe lane and serve as bridge for PCI X 133MHz secondary bus T...

Page 64: ...rity DDR2 400 MHz Mini DIMM to provide Intel RAID cache Mini DIMM capacities supported range from 128MB to 1GB Note See the Intel Server Board S5000PAL Tested Memory List for a list of Intel validated...

Page 65: ...SATA Backplane Layout The hot swap backplane installs on the back side of the hot swap drive bay inside the chassis Alignment features on the chassis and backplane assembly make for easy tool less ins...

Page 66: ...6 th Hard Drive or SATA Tape Drive E Midplane Connectors C IDE Connector Notes To prevent the backplane from flexing when installing or removing hard drives from the drive bay make sure the mid plane...

Page 67: ...29P SAS SATA HDD2 Connector 29P SAS SATA HDD3 Connector 29P SEEPROM Connector HBA Connector EEPROM LM75 SAS SATA HDD4 Connector 29P 64P Front Panel Connector to Front Panel Board 4P USB Connector for...

Page 68: ...a RAID configuration the RAID controller will have control over the fault LED and it may exhibit different behavior Table 40 Hard Drive LED Function Definitions Status LED Definition GREEN HDD Activi...

Page 69: ...ompact design The control panel assembly comes pre assembled and is modular in design The control panel assembly module slides into a slot on the front of the chassis and is blind mated with a slot co...

Page 70: ...ocate the server you re working on from behind a rack of servers C Reset Button Reboots and initializes the system D NMI Button Pressing the recessed button with a paper clip or pin puts the server in...

Page 71: ...sk Activity Off Off 3 No hard disk activity Blue On Identify active via command or button System Identification Off Off No Identification Notes 1 Blink rate is 1 Hz with at 50 duty cycle 2 The amber s...

Page 72: ...plied to the server Control Panel buttons are disabled until BMC initialization is complete Green Solid on Ok System booted and ready Green Blink Degraded System degraded Unable to use all of the inst...

Page 73: ...up Once BMC initialization has completed the status LED will stop blinking and the power button functionality is restored and can be used to turn on the Server 7 2 3 Drive Activity LED The drive acti...

Page 74: ...Table 47 Video Connector J1A1 Description Pin Pin Description VGA_RED 1 9 GND VGA_GREEN 2 10 GND VGA_BLUE 3 11 Unused Unused 4 12 VGA_DDCDAT GND 5 13 VGA_HSYNC_L GND 6 14 VGA_VSYNC_L VGA_INUSE_L 7 15...

Page 75: ...ct All control panel signals are directed through a single 64 pin card edge connector eliminating the need for any cables When installed into the chassis control panel bay the control panel card edge...

Page 76: ...B10 GND A11 GND B11 FP_SYS_FLT_LED1_R_L A12 GND B12 FP_ID_SW_L A13 FP_RST_BTN_L B13 FP_ID_LED_R_L A14 GND B14 NC_IPMB_5VSB_SDA A15 NC_FP_CHASSIS_L B15 NC_IPMB_5VSB_SCL A16 GND B16 GND A17 BP_I2C_5V_SD...

Page 77: ...el Local Control Panel module is designed so that it can be adjusted for use with or without an outer front bezel TP02113 Figure 44 Intel Local Control Panel Assembly Module The following diagram prov...

Page 78: ...ty Disk Activity Off Off 3 No hard disk activity Blue On Identify active via command or button System Identification Off Off No Identification Notes 1 Blink rate is 1 Hz with at 50 duty cycle 2 The am...

Page 79: ...pplied to the server Control Panel buttons are disabled until BMC initialization is complete Green Solid on Ok System booted and ready Green Blink Degraded System degraded Unable to use all of the ins...

Page 80: ...ng up Once BMC initialization has completed the status LED will stop blinking and the power button functionality is restored and can be used to turn on the server 8 1 3 Drive Activity LED The drive ac...

Page 81: ...r board and control panel interface board The 50 pin connectors are attached using a small 50 pin flat cable USB signals from the card edge connector are routed to the control panel interface board th...

Page 82: ...HDD_FAULT_LED_R_L A27 PWR_FP_USB3 B27 HDD_LED_ACT_R_L A28 GND B28 FP_PWR_LED_R_L A29 GND B29 FP_SYS_FLT_LED2_R_L A30 USB_DP3_FP B30 GND A31 USB_DN3_FP B31 GND A32 GND B32 NC_RST_P6_PWRGOOD Table 53 I...

Page 83: ...de onto the assembly where a latching mechanism than holds each riser in place Holding down the latch releases the risers for easy removal When re inserting the riser assembly into the chassis tabs on...

Page 84: ...either PCI Express slot While each slot can accommodate a x8 card each slot will only support x4 bus speeds The full height riser slot J4F1 implements Intel Adaptive Slot Technology This 280 pin conn...

Page 85: ...22 5 00 0 197 6 00 0 236 R2 00 0 079 Pad 3 50 0 138 Detail A Scale 2 000 Side 2 Ground Pad 2X R1 00 0 039 2X 67 75 2 667 66 17 2 605 46 98 1 850 41 98 1 653 24 32 0 958 23 32 0 918 19 32 0 761 10 90 0...

Page 86: ...0 063 20 74 75 2 943 68 90 2 713 2X 67 78 2 668 2X 47 46 1 868 6 25 0 246 70 43 2 773 67 67 2 664 58 18 2 291 2X 17 15 0 675 8 40 0 331 3 50 0 138 0 00 0 000 50 11 1 973 38 29 1 508 35 40 1 394 32 20...

Page 87: ...197 10 76 0 424 1 60 0 063 74 75 2 943 68 90 2 713 58 18 2 291 38 29 1 508 6 25 0 246 3 50 0 138 72 84 2 868 67 67 2 664 2X 17 15 0 675 8 40 0 331 0 00 0 000 52 52 2 068 35 40 1 394 32 20 1 268 27 40...

Page 88: ...5 2 943 68 90 2 713 70 50 2 776 6 25 0 246 8 40 0 331 72 84 2 868 67 67 2 664 17 15 0 675 2X 8 40 0 331 3 50 0 138 0 00 0 000 52 52 2 068 38 39 1 508 58 18 2 291 35 40 1 394 32 20 1 268 27 40 1 079 22...

Page 89: ...t Two RJ45 NIC connectors for 10 100 1000 Mb connections Two USB 2 0 ports Video Connector Internal connectors headers One USB port header capable of providing two USB 2 0 ports One DH10 Serial A head...

Page 90: ...rds Intel Server System SR2500AL Revision 1 6 Intel order number D31980 009 78 TP02071 M N O L J K V U S T R W Q P PP MM LL KK II HH GG FF EE DD CC BB AA Z Y X B A E D F H G C I NN OO QQ JJ Figure 51...

Page 91: ...5000X Memory Controller Hub MCH II SATA 5 O CPU 1 Connector JJ SATA SW RAID 5 Activation Key Connector P CPU 2 Connector KK Intel Remote Management Module RMM Connector Q CPU 1 Fan Header LL System R...

Page 92: ...tion unpackaged 5 Hz to 500 Hz 2 20 g RMS random Shock operating Half sine 2 g peak 11 mSec ESD 15kV except I O port 8KV per Intel Environmental test specification System Cooling Requirement in BTU Hr...

Page 93: ...recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med bat...

Page 94: ...ire additional EMC compliance testing For more information please contact your local Intel Representative This is an FCC Class A device and its use is intended for a commercial type market place 11 5...

Page 95: ...of the FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept interference receive including inte...

Page 96: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference...

Page 97: ...ppareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e...

Page 98: ...ber and the following warning is located on the product safety label which is located on the bottom side pedestal orientation or side rack mount configuration 11 6 7 RRL Korea Following is the RRL cer...

Page 99: ...on Caused by Electronic Information Products EIP 39 Referred to as China RoHS Mark requires to be applied to retail products only Mark used is the Environmental Friendly Use Period EFUP Number represe...

Page 100: ...subassemblies must not contain restricted materials as defined in Intel s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers http supplier intel com ehs environmenta...

Page 101: ...hinese 2 Multiple Power Cords 60950 Safety Requirement Applied to product if more than one power cord is used German Dieses Ger te hat mehr als ein Stromkabel Um eine Gefahr des elektrischen Schlages...

Page 102: ...10BEnvironmental and Regulatory Specifications Intel Server System SR2500AL Revision 1 6 Intel order number D31980 009 90 This page intentionally left blank...

Page 103: ...Records for this chassis on to the server board Failure to do so may result in possible false errors being reported to the System Event Log It is best to download the latest FRUSDR Utility for your pa...

Page 104: ...ree colors green red and amber The POST codes are divided into two nibbles an upper nibble and a lower nibble Each bit in the upper nibble is represented by a red LED and each bit in the lower nibble...

Page 105: ...FF G A G Initializing memory such as ECC init 0x28h G OFF R OFF Testing memory PCI Bus 0x50h OFF R OFF R Enumerating PCI busses 0x51h OFF R OFF A Allocating resources to PCI busses 0x52h OFF R G R Hot...

Page 106: ...h A G R R Enabling configuring a removable media device Boot Device Selection 0xD0 R R OFF R Trying boot device selection 0xD1 R R OFF A Trying boot device selection 0xD2 R R G R Trying boot device se...

Page 107: ...5h R A R A Exiting Sleep state 0xF8h A R R R Operating system has requested EFI to close boot services ExitBootServices has been called 0xF9h A R R A Operating system has switched to virtual address m...

Page 108: ...nditions Beep codes are sounded each time the problem is discovered such as on each power up attempt but are not sounded continuously Codes that are common across all Intel server boards and systems t...

Page 109: ...anagement Port FP Front Panel FRB Fault Resilient Boot FRU Field Replaceable Unit LCD Liquid Crystal Display LPC Low Pin Count MTBF Mean Time Between Failure MTTR Mean Time to Repair OTP Over temperat...

Page 110: ...rmation o Intel Server Board S5000PAL Technical Product Specification o Intel 5000 Series Chipsets Server Board Family Datasheet o Intel Server Chassis SR2500 Power Distribution Board for 750W Power S...

Reviews: