5.3.2.3 Degraded
Conditions
A degraded condition is associated with the following events:
•
Non-redundant power supply operation. This applies only when the BMC is configured
for a redundant power subsystem.
•
One or more processors are disabled by Fault Reliant Booting (FRB) or BIOS.
•
BIOS has disabled or mapped out some of the system memory.
5.3.3
Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the onboard hard disk
controllers. The server boards SE7500WV2 and SE7501WV2 also provides a header giving
access to this LED for add-in controllers.
5.3.4
System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is
especially useful when the system is installed when in a high density rack or cabinet that is
populated with several similar systems. The system ID LED is illuminated when the System ID
button on the front panel is pressed or it can be illuminated remotely through server
management software.