SR2300 2U Server Chassis Technical Product Specification
Revision 1.2
Intel Order Number A94546-004
61
12. Environmental Limits
12.1 System Level Environmental Limits
The table below defines the system level operating and non-operating environmental limits
(Office or Computer room Environment)
Table 30. System Office Environment Summary
Parameter
Limits
Operating Temperature
+10
°
C to +35
°
C with the maximum rate of change not to exceed 10
°
C per hour.
Non-Operating
Temperature
-40
°
C to +70
°
C
Non-Operating Humidity
90%, non-condensing @ 35
°
C
Acoustic noise
Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office ambient
temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2 degrees C)
Operating Shock
No errors with a half sine wave shock of 2G (with 11 millisecond duration).
Package Shock
Operational after a 24 inch free fall, although cosmetic damage may be present
(Chassis Weight 40-80 lbs)
ESD
+/-15kV per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
1826 BTU/hour
12.2 System Environmental Testing
The system will be tested per the Environmental Standards Handbook, Intel Doc.#662394-05.
These tests includes:
•
Temperature Operating and Non-Operating
•
Humidity Non-Operating
•
Packaged and Unpackaged Shock
•
Packaged and Unpackaged Vibration
•
AC Voltage, Freq. & Source Interrupt
•
AC Surge
•
Acoustics
•
ESD
•
EMC Radiated and Conducted Emissions Certifications