6. First fit the front of the module into the back panel slot(s), and then attach the
module to the server board connector and engage the standoffs (see letter “C” in
Figure 88
).
Figure 88. Installing the I/O Expansion Module to the Server System
7. Install the processor air duct. For instructions, see
“Installing the Processor Air
Duct” on page 57
.
8. Install the PCI riser assembly into the server system. For instructions, see
“Installing the PCI Riser Assembly” on page 51
.
Removing the I/O Expansion Module
To remove the I/O expansion module, follow these steps:
1. Remove the PCI riser assembly. For instructions, see
“Removing the PCI Riser
Assembly” on page 50
.
2. Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct” on page 56
.
3. Disconnect the I/O expansion module from the server board connector and the
standoffs and remove the module out of the server system (see letter “A” in
Figure 89
.
4. Remove the standoffs from the server board (see letter “B” in
Figure 89
).
1-Socket
I/O Exp. Module
Standoff
Hole
2-Socket
I/O Exp. Module
Snap
Standoff
Server Board
I/O Connector 1
A
B
C
Filler Panels
AF00
3
006
Summary of Contents for SR2600URLX
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Page 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Page 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Page 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...