Replacing the Power Distribution Module
To replace the power distribution module, follow these steps:
1. If installed, remove the PCI riser assembly. For instructions, see
“Removing the
PCI Riser Assembly” on page 50
.
2. If installed, remove the processor air duct. For instructions, see
“Removing the
Processor Air Duct” on page 56
.
3. Remove the large air baffle. For instructions, see
“Removing the Large Air Baffle”
on page 70
.
4. Remove the fan module assembly. For instructions, see
“Replacing a Fan Module”
on page 128
.
5. Disconnect all power cables from the server board, backplane, and midplane.
6. Remove the hot-swap power supply/supplies. For instructions, see step 1 in
“Replacing the Power Supply” on page 121
.
7. Remove the two screws to release the module (see letter “A” in
Figure 116
).
AF000023
Summary of Contents for SR2600URLX
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Page 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Page 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Page 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...