58
Intel
®
Server System SR2600UR/SR2625UR Service Guide
3. Locate the DIMM sockets (see
Figure 40
).
Figure 40. Installing the Memory
4. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the
open position (see letter “A” in
Figure 40
).
5. Holding the DIMM by the edges, remove it from its anti-static package.
6. Position the DIMM above the socket. Align the notch on the bottom edge of the
DIMM with the key in the DIMM socket (see letter “B” in
Figure 40
- the arrow is
pointing to the key in the socket).
7. Insert the bottom edge of the DIMM into the socket.
8. When the DIMM is inserted, push down on the top edge of the DIMM until the
retaining clips snap into place (see letter “C” in
Figure 40
). Make sure the clips are
firmly in place (see letter “D” in
Figure 40
).
AF002884
DIMM B2
DIMM A1
DIMM A2
DIMM B1
DIMM C2
DIMM C1
DIMM F1
DIMM F2
DIMM E1
DIMM D2
DIMM D1
DIMM E2
D
A
B
E
C