Figure 45. Installing the Processor
12. Close the CPU load plate all the way (see letter “A” in
Figure 46
).
13. Close the socket lever completely and ensure that the load plate tab engages under
the socket lever when fully closed (see letter “B” in
Figure 46
).
Figure 46. Closing the Load Plate
14. Install the heatsink. For instructions, see
“Installing the Heatsink” on page 62
.
Installing the Heatsink
You must install the processor before installing the heatsink. For instructions, see
“Installing the Processor” on page 60
.
Caution:
Improper installation can damage the heatsink. Pay close attention to the steps and
perform each step exactly as indicated to avoid damage.
Caution:
The heatsink has Thermal Interface Material (TIM) located on the bottom of it. Use
caution when you unpack the heatsink so you do not damage the TIM.
Note:
New unused heatsinks have adequate TIM on the bottom. If you are reusing a heatsink
from replacing a processor, make sure there is adequate TIM present on the heatsink to
support processor cooling.
A
AF002839
Orientation Notch
Orientation Post
A
B
AF002840
Summary of Contents for SR2600URLX
Page 4: ...iv Intel Server System SR2600UR SR2625UR Service Guide...
Page 8: ...viii Intel Server System SR2600UR SR2625UR Service Guide...
Page 18: ...xviii Intel Server System SR2600UR SR2625UR Service Guide...
Page 20: ...xx Intel Server System SR2600UR SR2625UR Service Guide...
Page 26: ...6 Intel Server System SR2600UR SR2625UR Service Guide...
Page 170: ...152 Intel Server System SR2600UR SR2625UR Service Guide...
Page 180: ...162 Intel Server System SR2600UR SR2625UR Service Guide...
Page 204: ...186 Intel Server System SR2600UR SR2625UR Service Guide...
Page 228: ...210 Intel Server System SR2600UR SR2625UR Service Guide...